420 W TOPCon solar panel with 108 cells. Voc 37.9 V · Isc 14.1 A · TcVoc -0.23%/°C.
Select the panel you want to replace
116 panels found · 4223 panels excluded
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 37.92 V | 0.1% |
| Vmpp | 31.6 V | 31.32 V | 0.9% |
| Isc | 14.1 A | 13.99 A | 0.8% |
| Impp | 13.29 A | 13.25 A | 0.3% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 38.11 V | 0.6% |
| Vmpp | 31.6 V | 31.51 V | 0.3% |
| Isc | 14.1 A | 14.07 A | 0.2% |
| Impp | 13.29 A | 13.33 A | 0.3% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 38.09 V | 0.5% |
| Vmpp | 31.6 V | 31.46 V | 0.4% |
| Isc | 14.1 A | 14.09 A | 0.1% |
| Impp | 13.29 A | 13.36 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 37.92 V | 0.1% |
| Vmpp | 31.6 V | 31.32 V | 0.9% |
| Isc | 14.1 A | 13.99 A | 0.8% |
| Impp | 13.29 A | 13.26 A | 0.2% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
410 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 37.8 V | 0.3% |
| Vmpp | 31.6 V | 31.52 V | 0.3% |
| Isc | 14.1 A | 14.07 A | 0.2% |
| Impp | 13.29 A | 13.01 A | 2.1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
410 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 37.8 V | 0.3% |
| Vmpp | 31.6 V | 31.52 V | 0.3% |
| Isc | 14.1 A | 14.07 A | 0.2% |
| Impp | 13.29 A | 13.01 A | 2.1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
430 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 38.3 V | 1.1% |
| Vmpp | 31.6 V | 31.8 V | 0.6% |
| Isc | 14.1 A | 14.29 A | 1.3% |
| Impp | 13.29 A | 13.52 A | 1.7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 37.86 V | 0.1% |
| Vmpp | 31.6 V | 31.27 V | 1.0% |
| Isc | 14.1 A | 14.01 A | 0.6% |
| Impp | 13.29 A | 13.28 A | 0.1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 37.99 V | 0.2% |
| Vmpp | 31.6 V | 31.75 V | 0.5% |
| Isc | 14.1 A | 14.16 A | 0.4% |
| Impp | 13.29 A | 13.07 A | 1.7% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 37.99 V | 0.2% |
| Vmpp | 31.6 V | 31.75 V | 0.5% |
| Isc | 14.1 A | 14.16 A | 0.4% |
| Impp | 13.29 A | 13.07 A | 1.7% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
415 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 37.95 V | 0.1% |
| Vmpp | 31.6 V | 31.58 V | 0.1% |
| Isc | 14.1 A | 14.02 A | 0.6% |
| Impp | 13.29 A | 13.14 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.26 %/°C | ±0.030 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 37.9 V | 38.32 V | 1.1% |
| Vmpp | 31.6 V | 31.7 V | 0.3% |
| Isc | 14.1 A | 14.09 A | 0.1% |
| Impp | 13.29 A | 13.41 A | 0.9% |
| TcVoc | -0.23 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
37.9 V
Vmpp
31.6 V
Isc
14.1 A
Impp
13.29 A
TcVoc
-0.23 %/°C
TcPmax
-0.29 %/°C
Pmax
420 W
Cells
108
Bifaciality
80%
Length
1722 mm
Width
1134 mm
Thickness
30 mm
Weight
24 kg
The Sun Earth DXM8-54HBG 420W is a 420 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| DXM8-54HBG 410W | 410 W | 37.4 V | 13.92 A |
| DXM8-54HBG 430W | 430 W | 38.3 V | 14.29 A |
| DXM8-54HBG 440W | 440 W | 38.7 V | 14.46 A |
| DXM8-54HBG 450W | 450 W | 39.1 V | 14.62 A |
| DXM8-54HBG 455W | 455 W | 39.3 V | 14.7 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 37.9 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Sun Earth DXM8-54HBG 420W.