600 W TOPCon solar panel with 144 cells. Voc 52.1 V · Isc 14.64 A · TcVoc -0.23%/°C.
Select the panel you want to replace
187 panels found · 4152 panels excluded
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 52.1 V | 0.0% |
| Vmpp | 42.9 V | 42.9 V | 0.0% |
| Isc | 14.64 A | 14.64 A | 0.0% |
| Impp | 13.99 A | 13.99 A | 0.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 52.07 V | 0.1% |
| Vmpp | 42.9 V | 43.04 V | 0.3% |
| Isc | 14.64 A | 14.55 A | 0.6% |
| Impp | 13.99 A | 13.83 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 51.7 V | 0.8% |
| Vmpp | 42.9 V | 42.7 V | 0.5% |
| Isc | 14.64 A | 14.52 A | 0.8% |
| Impp | 13.99 A | 13.82 A | 1.2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 52.5 V | 0.8% |
| Vmpp | 42.9 V | 43.1 V | 0.5% |
| Isc | 14.64 A | 14.76 A | 0.8% |
| Impp | 13.99 A | 14.15 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 51.7 V | 0.8% |
| Vmpp | 42.9 V | 42.7 V | 0.5% |
| Isc | 14.64 A | 14.52 A | 0.8% |
| Impp | 13.99 A | 13.82 A | 1.2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 52.5 V | 0.8% |
| Vmpp | 42.9 V | 43.1 V | 0.5% |
| Isc | 14.64 A | 14.76 A | 0.8% |
| Impp | 13.99 A | 14.15 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 52.02 V | 0.2% |
| Vmpp | 42.9 V | 43.41 V | 1.2% |
| Isc | 14.64 A | 14.36 A | 1.9% |
| Impp | 13.99 A | 13.59 A | 2.9% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 51.95 V | 0.3% |
| Vmpp | 42.9 V | 43.76 V | 2.0% |
| Isc | 14.64 A | 14.62 A | 0.1% |
| Impp | 13.99 A | 13.83 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 52.05 V | 0.1% |
| Vmpp | 42.9 V | 43.25 V | 0.8% |
| Isc | 14.64 A | 14.66 A | 0.1% |
| Impp | 13.99 A | 13.89 A | 0.7% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 51.94 V | 0.3% |
| Vmpp | 42.9 V | 43.13 V | 0.5% |
| Isc | 14.64 A | 14.64 A | 0.0% |
| Impp | 13.99 A | 13.91 A | 0.6% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
595 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 52.24 V | 0.3% |
| Vmpp | 42.9 V | 43.59 V | 1.6% |
| Isc | 14.64 A | 14.42 A | 1.5% |
| Impp | 13.99 A | 13.65 A | 2.4% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.1 V | 52.27 V | 0.3% |
| Vmpp | 42.9 V | 43.19 V | 0.7% |
| Isc | 14.64 A | 14.61 A | 0.2% |
| Impp | 13.99 A | 13.9 A | 0.6% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
52.1 V
Vmpp
42.9 V
Isc
14.64 A
Impp
13.99 A
TcVoc
-0.23 %/°C
TcPmax
-0.29 %/°C
Pmax
600 W
Cells
144
Bifaciality
80%
Length
2278 mm
Width
1134 mm
Thickness
30 mm
Weight
32 kg
The Sun Earth DXM8-72HBG 600W is a 600 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| DXM8-72HBG 560W | 560 W | 50.5 V | 14.11 A |
| DXM8-72HBG 570W | 570 W | 50.9 V | 14.25 A |
| DXM8-72HBG 580W | 580 W | 51.3 V | 14.39 A |
| DXM8-72HBG 590W | 590 W | 51.7 V | 14.52 A |
| DXM8-72HBG 610W | 610 W | 52.5 V | 14.76 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 52.1 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Sun Earth DXM8-72HBG 600W.