490 W PERC solar panel with 150 cells. Voc 51.3 V · Isc 12.14 A · TcVoc -0.25%/°C.
Select the panel you want to replace
17 panels found · 4322 panels excluded
490 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.3 V | 0.0% |
| Vmpp | 42.4 V | 42.4 V | 0.0% |
| Isc | 12.14 A | 12.14 A | 0.0% |
| Impp | 11.56 A | 11.56 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
485 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.1 V | 0.4% |
| Vmpp | 42.4 V | 42.2 V | 0.5% |
| Isc | 12.14 A | 12.07 A | 0.6% |
| Impp | 11.56 A | 11.49 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
495 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.5 V | 0.4% |
| Vmpp | 42.4 V | 42.6 V | 0.5% |
| Isc | 12.14 A | 12.21 A | 0.6% |
| Impp | 11.56 A | 11.63 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
485 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.1 V | 0.4% |
| Vmpp | 42.4 V | 42.2 V | 0.5% |
| Isc | 12.14 A | 12.07 A | 0.6% |
| Impp | 11.56 A | 11.49 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
495 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.5 V | 0.4% |
| Vmpp | 42.4 V | 42.6 V | 0.5% |
| Isc | 12.14 A | 12.21 A | 0.6% |
| Impp | 11.56 A | 11.63 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
505 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.23 V | 0.1% |
| Vmpp | 42.4 V | 43.1 V | 1.7% |
| Isc | 12.14 A | 12.53 A | 3.2% |
| Impp | 11.56 A | 11.74 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
500 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.7 V | 0.8% |
| Vmpp | 42.4 V | 42.8 V | 0.9% |
| Isc | 12.14 A | 12.28 A | 1.2% |
| Impp | 11.56 A | 11.69 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
500 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.7 V | 0.8% |
| Vmpp | 42.4 V | 42.8 V | 0.9% |
| Isc | 12.14 A | 12.28 A | 1.2% |
| Impp | 11.56 A | 11.69 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
500 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.01 V | 0.6% |
| Vmpp | 42.4 V | 42.88 V | 1.1% |
| Isc | 12.14 A | 12.46 A | 2.6% |
| Impp | 11.56 A | 11.68 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
495 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 50.79 V | 1.0% |
| Vmpp | 42.4 V | 42.66 V | 0.6% |
| Isc | 12.14 A | 12.39 A | 2.1% |
| Impp | 11.56 A | 11.62 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
490 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 50.57 V | 1.4% |
| Vmpp | 42.4 V | 42.44 V | 0.1% |
| Isc | 12.14 A | 12.32 A | 1.5% |
| Impp | 11.56 A | 11.56 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
510 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.3 V | 51.45 V | 0.3% |
| Vmpp | 42.4 V | 43.32 V | 2.2% |
| Isc | 12.14 A | 12.6 A | 3.8% |
| Impp | 11.56 A | 11.8 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
51.3 V
Vmpp
42.4 V
Isc
12.14 A
Impp
11.56 A
TcVoc
-0.25 %/°C
TcPmax
-0.34 %/°C
Pmax
490 W
Cells
150
Length
2187 mm
Width
1102 mm
Thickness
35 mm
Weight
26.5 kg
The Trina Solar TSM-490-DE18M.08(II) is a 490 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| TSM-485-DE18M.08(II) | 485 W | 51.1 V | 12.07 A |
| TSM-495-DE18M.08(II) | 495 W | 51.5 V | 12.21 A |
| TSM-500-DE18M.08(II) | 500 W | 51.7 V | 12.28 A |
| TSM-505-DE18M.08(II) | 505 W | 51.9 V | 12.35 A |
| TSM-510-DE18M.08(II) | 510 W | 52.1 V | 12.42 A |
The most critical specs to match are: cell count (must be exactly 150), Voc close to 51.3 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Trina Solar TSM-490-DE18M.08(II).