505 W TOPCon solar panel with 108 cells. Voc 40.3 V · Isc 15.89 A · TcVoc -0.24%/°C.
Select the panel you want to replace
216 panels found · 4123 panels excluded
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.4 V | 0.2% |
| Vmpp | 33.5 V | 33.5 V | 0.0% |
| Isc | 15.89 A | 15.89 A | 0.0% |
| Impp | 15.09 A | 15.08 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.23 V | 0.2% |
| Vmpp | 33.5 V | 33.51 V | 0.0% |
| Isc | 15.89 A | 15.93 A | 0.3% |
| Impp | 15.09 A | 15.07 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
500 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.1 V | 0.5% |
| Vmpp | 33.5 V | 33.3 V | 0.6% |
| Isc | 15.89 A | 15.86 A | 0.2% |
| Impp | 15.09 A | 15.03 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
500 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.29 V | 0.0% |
| Vmpp | 33.5 V | 33.28 V | 0.7% |
| Isc | 15.89 A | 15.89 A | 0.0% |
| Impp | 15.09 A | 15.03 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.35 V | 0.1% |
| Vmpp | 33.5 V | 33.53 V | 0.1% |
| Isc | 15.89 A | 15.9 A | 0.1% |
| Impp | 15.09 A | 15.06 A | 0.2% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.24 V | 0.1% |
| Vmpp | 33.5 V | 33.6 V | 0.3% |
| Isc | 15.89 A | 15.88 A | 0.1% |
| Impp | 15.09 A | 15.03 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.24 V | 0.1% |
| Vmpp | 33.5 V | 33.94 V | 1.3% |
| Isc | 15.89 A | 15.92 A | 0.2% |
| Impp | 15.09 A | 14.88 A | 1.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.24 V | 0.1% |
| Vmpp | 33.5 V | 33.94 V | 1.3% |
| Isc | 15.89 A | 15.92 A | 0.2% |
| Impp | 15.09 A | 14.88 A | 1.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.48 V | 0.4% |
| Vmpp | 33.5 V | 33.44 V | 0.2% |
| Isc | 15.89 A | 15.97 A | 0.5% |
| Impp | 15.09 A | 15.11 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
505 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.22 V | 0.2% |
| Vmpp | 33.5 V | 33.25 V | 0.7% |
| Isc | 15.89 A | 15.95 A | 0.4% |
| Impp | 15.09 A | 15.19 A | 0.7% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.42 V | 0.3% |
| Vmpp | 33.5 V | 33.45 V | 0.1% |
| Isc | 15.89 A | 16.02 A | 0.8% |
| Impp | 15.09 A | 15.25 A | 1.1% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
510 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.3 V | 40.43 V | 0.3% |
| Vmpp | 33.5 V | 33.71 V | 0.6% |
| Isc | 15.89 A | 15.98 A | 0.6% |
| Impp | 15.09 A | 15.13 A | 0.3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
40.3 V
Vmpp
33.5 V
Isc
15.89 A
Impp
15.09 A
TcVoc
-0.24 %/°C
TcPmax
-0.29 %/°C
Pmax
505 W
Cells
108
Bifaciality
80%
Length
1961 mm
Width
1134 mm
Thickness
30 mm
Weight
23.5 kg
The Trina Solar TSM-NEG18RC.27-505 is a 505 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| TSM-NEG18RC.27-495 | 495 W | 39.8 V | 15.83 A |
| TSM-NEG18RC.27-500 | 500 W | 40.1 V | 15.86 A |
| TSM-NEG18RC.27-510 | 510 W | 40.6 V | 15.93 A |
| TSM-NEG18RC.27-515 | 515 W | 40.9 V | 15.96 A |
| TSM-NEG18RC.27-520 | 520 W | 41.2 V | 15.99 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 40.3 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Trina Solar TSM-NEG18RC.27-505.