705 W TOPCon solar panel with 132 cells. Voc 48.1 V · Isc 18.55 A · TcVoc -0.25%/°C.
Select the panel you want to replace
29 panels found · 4310 panels excluded
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 47.9 V | 0.4% |
| Vmpp | 40.4 V | 40.2 V | 0.5% |
| Isc | 18.55 A | 18.5 A | 0.3% |
| Impp | 17.46 A | 17.42 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.3 V | 0.4% |
| Vmpp | 40.4 V | 40.6 V | 0.5% |
| Isc | 18.55 A | 18.61 A | 0.3% |
| Impp | 17.46 A | 17.49 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
695 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.3 V | 0.4% |
| Vmpp | 40.4 V | 40.3 V | 0.2% |
| Isc | 18.55 A | 18.28 A | 1.5% |
| Impp | 17.46 A | 17.25 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.5 V | 0.8% |
| Vmpp | 40.4 V | 40.8 V | 1.0% |
| Isc | 18.55 A | 18.66 A | 0.6% |
| Impp | 17.46 A | 17.53 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.51 V | 0.9% |
| Vmpp | 40.4 V | 40.71 V | 0.8% |
| Isc | 18.55 A | 18.22 A | 1.8% |
| Impp | 17.46 A | 17.2 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.6 V | 1.0% |
| Vmpp | 40.4 V | 40.5 V | 0.2% |
| Isc | 18.55 A | 18.32 A | 1.2% |
| Impp | 17.46 A | 17.29 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.7 V | 1.2% |
| Vmpp | 40.4 V | 41 V | 1.5% |
| Isc | 18.55 A | 18.72 A | 0.9% |
| Impp | 17.46 A | 17.56 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.76 V | 1.4% |
| Vmpp | 40.4 V | 40.85 V | 1.1% |
| Isc | 18.55 A | 18.26 A | 1.6% |
| Impp | 17.46 A | 17.27 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.8 V | 1.5% |
| Vmpp | 40.4 V | 40.7 V | 0.7% |
| Isc | 18.55 A | 18.36 A | 1.0% |
| Impp | 17.46 A | 17.33 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.6 V | 1.0% |
| Vmpp | 40.4 V | 40.5 V | 0.2% |
| Isc | 18.55 A | 18.67 A | 0.6% |
| Impp | 17.46 A | 17.78 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.32 %/°C | ±0.030 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.6 V | 1.0% |
| Vmpp | 40.4 V | 40.5 V | 0.2% |
| Isc | 18.55 A | 18.67 A | 0.6% |
| Impp | 17.46 A | 17.78 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.32 %/°C | ±0.030 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.1 V | 48.9 V | 1.7% |
| Vmpp | 40.4 V | 41.2 V | 2.0% |
| Isc | 18.55 A | 18.77 A | 1.2% |
| Impp | 17.46 A | 17.6 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.1 V
Vmpp
40.4 V
Isc
18.55 A
Impp
17.46 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
705 W
Cells
132
Length
2384 mm
Width
1303 mm
Thickness
33 mm
Weight
38.8 kg
The UKSOL UKS-S132-M12N-705-BG is a 705 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| UKS-S132-M12N-700-BG | 700 W | 47.9 V | 18.5 A |
| UKS-S132-M12N-710-BG | 710 W | 48.3 V | 18.61 A |
| UKS-S132-M12N-715-BG | 715 W | 48.5 V | 18.66 A |
| UKS-S132-M12N-720-BG | 720 W | 48.7 V | 18.72 A |
| UKS-S132-M12N-725-BG | 725 W | 48.9 V | 18.77 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.1 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original UKSOL UKS-S132-M12N-705-BG.