465 W IBC solar panel with 108 cells. Voc 39.89 V · Isc 14.67 A · TcVoc -0.22%/°C.
Select the panel you want to replace
183 panels found · 4156 panels excluded
470 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.01 V | 0.3% |
| Vmpp | 33.55 V | 33.58 V | 0.1% |
| Isc | 14.67 A | 14.76 A | 0.6% |
| Impp | 13.86 A | 13.99 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
470 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.2 V | 0.8% |
| Vmpp | 33.55 V | 33.79 V | 0.7% |
| Isc | 14.67 A | 14.73 A | 0.4% |
| Impp | 13.86 A | 13.91 A | 0.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
475 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.15 V | 0.7% |
| Vmpp | 33.55 V | 33.74 V | 0.6% |
| Isc | 14.67 A | 14.84 A | 1.2% |
| Impp | 13.86 A | 14.08 A | 1.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 39.9 V | 0.0% |
| Vmpp | 33.55 V | 33.44 V | 0.3% |
| Isc | 14.67 A | 14.37 A | 2.0% |
| Impp | 13.86 A | 13.31 A | 4.0% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
475 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.3 V | 1.0% |
| Vmpp | 33.55 V | 33.91 V | 1.1% |
| Isc | 14.67 A | 14.81 A | 1.0% |
| Impp | 13.86 A | 14.01 A | 1.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
470 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.5 V | 1.5% |
| Vmpp | 33.55 V | 33.64 V | 0.3% |
| Isc | 14.67 A | 14.82 A | 1.0% |
| Impp | 13.86 A | 13.98 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.1 V | 0.5% |
| Vmpp | 33.55 V | 33.64 V | 0.3% |
| Isc | 14.67 A | 14.45 A | 1.5% |
| Impp | 13.86 A | 13.38 A | 3.5% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 39.97 V | 0.2% |
| Vmpp | 33.55 V | 33.39 V | 0.5% |
| Isc | 14.67 A | 13.94 A | 5.0% |
| Impp | 13.86 A | 13.48 A | 2.7% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
475 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 39.61 V | 0.7% |
| Vmpp | 33.55 V | 33.6 V | 0.1% |
| Isc | 14.67 A | 15.06 A | 2.7% |
| Impp | 13.86 A | 14.14 A | 2.0% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
480 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.42 V | 1.3% |
| Vmpp | 33.55 V | 34.05 V | 1.5% |
| Isc | 14.67 A | 14.91 A | 1.6% |
| Impp | 13.86 A | 14.1 A | 1.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.14 V | 0.6% |
| Vmpp | 33.55 V | 33.53 V | 0.1% |
| Isc | 14.67 A | 14.03 A | 4.4% |
| Impp | 13.86 A | 13.57 A | 2.1% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
475 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.89 V | 40.11 V | 0.6% |
| Vmpp | 33.55 V | 33.2 V | 1.0% |
| Isc | 14.67 A | 15.01 A | 2.3% |
| Impp | 13.86 A | 14.31 A | 3.2% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
39.89 V
Vmpp
33.55 V
Isc
14.67 A
Impp
13.86 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
465 W
Cells
108
Bifaciality
70%
Length
1800 mm
Width
1134 mm
Thickness
30 mm
Weight
22 kg
The Ulica Solar UL-465M-108CDGBT is a 465 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| UL-470M-108CDGBT | 470 W | 40.2 V | 14.73 A |
| UL-475M-108CDGBT | 475 W | 40.3 V | 14.81 A |
| UL-480M-108CDGBT | 480 W | 40.42 V | 14.91 A |
| UL-485M-108CDGBT | 485 W | 40.61 V | 14.98 A |
| UL-490M-108CDGBT | 490 W | 40.71 V | 15.06 A |
| UL-495M-108CDGBT | 495 W | 40.85 V | 15.13 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 39.89 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Ulica Solar UL-465M-108CDGBT.