600 W TOPCon solar panel with 156 cells. Voc 56.75 V · Isc 13.38 A · TcVoc -0.25%/°C.
Select the panel you want to replace
15 panels found · 4324 panels excluded
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 56.95 V | 0.4% |
| Vmpp | 45.93 V | 46.1 V | 0.4% |
| Isc | 13.38 A | 13.48 A | 0.7% |
| Impp | 13.06 A | 13.12 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 57.08 V | 0.6% |
| Vmpp | 45.93 V | 46.28 V | 0.8% |
| Isc | 13.38 A | 13.54 A | 1.2% |
| Impp | 13.06 A | 13.18 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 57.21 V | 0.8% |
| Vmpp | 45.93 V | 46.4 V | 1.0% |
| Isc | 13.38 A | 13.6 A | 1.6% |
| Impp | 13.06 A | 13.25 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 56.67 V | 0.1% |
| Vmpp | 45.93 V | 47.5 V | 3.4% |
| Isc | 13.38 A | 13.76 A | 2.8% |
| Impp | 13.06 A | 13.05 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 56.71 V | 0.1% |
| Vmpp | 45.93 V | 47.44 V | 3.3% |
| Isc | 13.38 A | 13.83 A | 3.4% |
| Impp | 13.06 A | 13.07 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 56.55 V | 0.4% |
| Vmpp | 45.93 V | 47.27 V | 2.9% |
| Isc | 13.38 A | 13.78 A | 3.0% |
| Impp | 13.06 A | 13.01 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 56.39 V | 0.6% |
| Vmpp | 45.93 V | 47.3 V | 3.0% |
| Isc | 13.38 A | 13.71 A | 2.5% |
| Impp | 13.06 A | 13 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 56.11 V | 1.1% |
| Vmpp | 45.93 V | 47.1 V | 2.5% |
| Isc | 13.38 A | 13.65 A | 2.0% |
| Impp | 13.06 A | 12.95 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 55.83 V | 1.6% |
| Vmpp | 45.93 V | 46.67 V | 1.6% |
| Isc | 13.38 A | 14.16 A | 5.8% |
| Impp | 13.06 A | 13.3 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 55.3 V | 2.6% |
| Vmpp | 45.93 V | 45.9 V | 0.1% |
| Isc | 13.38 A | 14.16 A | 5.8% |
| Impp | 13.06 A | 13.4 A | 2.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 55.1 V | 2.9% |
| Vmpp | 45.93 V | 45.7 V | 0.5% |
| Isc | 13.38 A | 14.11 A | 5.5% |
| Impp | 13.06 A | 13.35 A | 2.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56.75 V | 55.5 V | 2.2% |
| Vmpp | 45.93 V | 46.1 V | 0.4% |
| Isc | 13.38 A | 14.21 A | 6.2% |
| Impp | 13.06 A | 13.45 A | 3.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
56.75 V
Vmpp
45.93 V
Isc
13.38 A
Impp
13.06 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
600 W
Cells
156
Bifaciality
80%
Length
2465 mm
Width
1134 mm
Thickness
30 mm
Weight
32 kg
The Ulica Solar UL-600M-156ADGN is a 600 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| UL-605M-156ADGN | 605 W | 56.95 V | 13.48 A |
| UL-610M-156ADGN | 610 W | 57.08 V | 13.54 A |
| UL-615M-156ADGN | 615 W | 57.21 V | 13.6 A |
| UL-625M-156ADGN | 625 W | 56.95 V | 13.8 A |
The most critical specs to match are: cell count (must be exactly 156), Voc close to 56.75 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Ulica Solar UL-600M-156ADGN.