635 W TOPCon solar panel with 132 cells. Voc 47.5 V · Isc 16.9 A · TcVoc -0.25%/°C.
Select the panel you want to replace
55 panels found · 4284 panels excluded
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 47.3 V | 0.4% |
| Vmpp | 41 V | 40.81 V | 0.5% |
| Isc | 16.9 A | 16.83 A | 0.4% |
| Impp | 15.49 A | 15.44 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 47.08 V | 0.9% |
| Vmpp | 41 V | 40.7 V | 0.7% |
| Isc | 16.9 A | 16.77 A | 0.8% |
| Impp | 15.49 A | 15.36 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 46.9 V | 1.3% |
| Vmpp | 41 V | 40.5 V | 1.2% |
| Isc | 16.9 A | 16.7 A | 1.2% |
| Impp | 15.49 A | 15.31 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 48.2 V | 1.5% |
| Vmpp | 41 V | 41 V | 0.0% |
| Isc | 16.9 A | 16.02 A | 5.2% |
| Impp | 15.49 A | 15.01 A | 3.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 46.72 V | 1.6% |
| Vmpp | 41 V | 40.31 V | 1.7% |
| Isc | 16.9 A | 16.62 A | 1.7% |
| Impp | 15.49 A | 15.26 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 48.88 V | 2.9% |
| Vmpp | 41 V | 41 V | 0.0% |
| Isc | 16.9 A | 16.29 A | 3.6% |
| Impp | 15.49 A | 15.49 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 48.3 V | 1.7% |
| Vmpp | 41 V | 41 V | 0.0% |
| Isc | 16.9 A | 15.85 A | 6.2% |
| Impp | 15.49 A | 15 A | 3.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 48.7 V | 2.5% |
| Vmpp | 41 V | 40.99 V | 0.0% |
| Isc | 16.9 A | 16.17 A | 4.3% |
| Impp | 15.49 A | 15.37 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 48.1 V | 1.3% |
| Vmpp | 41 V | 41.35 V | 0.9% |
| Isc | 16.9 A | 15.9 A | 5.9% |
| Impp | 15.49 A | 14.88 A | 3.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 48.9 V | 2.9% |
| Vmpp | 41 V | 40.7 V | 0.7% |
| Isc | 16.9 A | 16.18 A | 4.3% |
| Impp | 15.49 A | 15.48 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 48.4 V | 1.9% |
| Vmpp | 41 V | 41.2 V | 0.5% |
| Isc | 16.9 A | 16.08 A | 4.9% |
| Impp | 15.49 A | 15.06 A | 2.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 47.5 V | 48.92 V | 3.0% |
| Vmpp | 41 V | 40.41 V | 1.4% |
| Isc | 16.9 A | 16.35 A | 3.3% |
| Impp | 15.49 A | 15.47 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
47.5 V
Vmpp
41 V
Isc
16.9 A
Impp
15.49 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
635 W
Cells
132
Bifaciality
80%
Length
2390 mm
Width
1140 mm
Thickness
30 mm
Weight
33 kg
The Ulica Solar UL-635M-132DDGN is a 635 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| UL-610M-132DDGN | 610 W | 46.54 V | 16.56 A |
| UL-615M-132DDGN | 615 W | 46.72 V | 16.62 A |
| UL-620M-132DDGN | 620 W | 46.9 V | 16.7 A |
| UL-625M-132DDGN | 625 W | 47.08 V | 16.77 A |
| UL-630M-132DDGN | 630 W | 47.3 V | 16.83 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 47.5 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Ulica Solar UL-635M-132DDGN.