645 W IBC solar panel with 132 cells. Voc 49.22 V · Isc 16.5 A · TcVoc -0.25%/°C.
Select the panel you want to replace
145 panels found · 4194 panels excluded
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.22 V | 0.0% |
| Vmpp | 41.3 V | 41.33 V | 0.1% |
| Isc | 16.5 A | 16.41 A | 0.5% |
| Impp | 15.62 A | 15.61 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
640 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.11 V | 0.2% |
| Vmpp | 41.3 V | 41.18 V | 0.3% |
| Isc | 16.5 A | 16.41 A | 0.5% |
| Impp | 15.62 A | 15.54 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
650 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.33 V | 0.2% |
| Vmpp | 41.3 V | 41.42 V | 0.3% |
| Isc | 16.5 A | 16.59 A | 0.5% |
| Impp | 15.62 A | 15.69 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.47 V | 0.5% |
| Vmpp | 41.3 V | 41.28 V | 0.0% |
| Isc | 16.5 A | 16.42 A | 0.5% |
| Impp | 15.62 A | 15.51 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.39 V | 0.3% |
| Vmpp | 41.3 V | 41.2 V | 0.2% |
| Isc | 16.5 A | 16.24 A | 1.6% |
| Impp | 15.62 A | 15.54 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.38 V | 0.3% |
| Vmpp | 41.3 V | 41.49 V | 0.5% |
| Isc | 16.5 A | 16.47 A | 0.2% |
| Impp | 15.62 A | 15.67 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.29 V | 0.1% |
| Vmpp | 41.3 V | 41.05 V | 0.6% |
| Isc | 16.5 A | 16.17 A | 2.0% |
| Impp | 15.62 A | 15.25 A | 2.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.06 V | 0.3% |
| Vmpp | 41.3 V | 41.18 V | 0.3% |
| Isc | 16.5 A | 16.35 A | 0.9% |
| Impp | 15.62 A | 15.55 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.38 V | 0.3% |
| Vmpp | 41.3 V | 40.79 V | 1.2% |
| Isc | 16.5 A | 16.46 A | 0.2% |
| Impp | 15.62 A | 15.57 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.18 V | 0.1% |
| Vmpp | 41.3 V | 40.62 V | 1.6% |
| Isc | 16.5 A | 16.41 A | 0.5% |
| Impp | 15.62 A | 15.52 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.3 V | 0.2% |
| Vmpp | 41.3 V | 41.06 V | 0.6% |
| Isc | 16.5 A | 16.51 A | 0.1% |
| Impp | 15.62 A | 15.6 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.3 V | 0.2% |
| Vmpp | 41.3 V | 41.06 V | 0.6% |
| Isc | 16.5 A | 16.51 A | 0.1% |
| Impp | 15.62 A | 15.6 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.22 V
Vmpp
41.3 V
Isc
16.5 A
Impp
15.62 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
645 W
Cells
132
Bifaciality
70%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
33.5 kg
The Ulica Solar UL-645M-132DDGB is a 645 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| UL-640M-132DDGB | 640 W | 49.11 V | 16.41 A |
| UL-650M-132DDGB | 650 W | 49.33 V | 16.59 A |
| UL-655M-132DDGB | 655 W | 49.45 V | 16.68 A |
| UL-660M-132DDGB | 660 W | 49.56 V | 16.77 A |
| UL-665M-132DDGB | 665 W | 49.68 V | 16.86 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.22 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Ulica Solar UL-645M-132DDGB.