695 W TOPCon solar panel with 132 cells. Voc 48.38 V · Isc 18.27 A · TcVoc -0.26%/°C.
Select the panel you want to replace
120 panels found · 4219 panels excluded
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.37 V | 0.0% |
| Vmpp | 40.29 V | 40.15 V | 0.3% |
| Isc | 18.27 A | 18.38 A | 0.6% |
| Impp | 17.25 A | 17.44 A | 1.1% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
690 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.18 V | 0.4% |
| Vmpp | 40.29 V | 40.09 V | 0.5% |
| Isc | 18.27 A | 18.23 A | 0.2% |
| Impp | 17.25 A | 17.21 A | 0.2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.58 V | 0.4% |
| Vmpp | 40.29 V | 40.49 V | 0.5% |
| Isc | 18.27 A | 18.31 A | 0.2% |
| Impp | 17.25 A | 17.29 A | 0.2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
695 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.42 V | 0.1% |
| Vmpp | 40.29 V | 40.35 V | 0.1% |
| Isc | 18.27 A | 18.28 A | 0.1% |
| Impp | 17.25 A | 17.22 A | 0.2% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
695 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.3 V | 0.2% |
| Vmpp | 40.29 V | 40.33 V | 0.1% |
| Isc | 18.27 A | 18.28 A | 0.1% |
| Impp | 17.25 A | 17.24 A | 0.1% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.57 V | 0.4% |
| Vmpp | 40.29 V | 40.31 V | 0.0% |
| Isc | 18.27 A | 18.43 A | 0.9% |
| Impp | 17.25 A | 17.49 A | 1.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.4 V | 0.0% |
| Vmpp | 40.29 V | 40.42 V | 0.3% |
| Isc | 18.27 A | 18.4 A | 0.7% |
| Impp | 17.25 A | 17.32 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.36 V | 0.0% |
| Vmpp | 40.29 V | 40.65 V | 0.9% |
| Isc | 18.27 A | 18.51 A | 1.3% |
| Impp | 17.25 A | 17.59 A | 2.0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
695 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.17 V | 0.4% |
| Vmpp | 40.29 V | 39.98 V | 0.8% |
| Isc | 18.27 A | 18.33 A | 0.3% |
| Impp | 17.25 A | 17.38 A | 0.8% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.3 V | 0.2% |
| Vmpp | 40.29 V | 40.7 V | 1.0% |
| Isc | 18.27 A | 18.38 A | 0.6% |
| Impp | 17.25 A | 17.33 A | 0.5% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
690 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.22 V | 0.3% |
| Vmpp | 40.29 V | 40.17 V | 0.3% |
| Isc | 18.27 A | 18.25 A | 0.1% |
| Impp | 17.25 A | 17.18 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.38 V | 48.4 V | 0.0% |
| Vmpp | 40.29 V | 40.61 V | 0.8% |
| Isc | 18.27 A | 18.47 A | 1.1% |
| Impp | 17.25 A | 17.36 A | 0.6% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.38 V
Vmpp
40.29 V
Isc
18.27 A
Impp
17.25 A
TcVoc
-0.26 %/°C
TcPmax
-0.3 %/°C
Pmax
695 W
Cells
132
Bifaciality
80%
Length
2384 mm
Width
1303 mm
Thickness
33 mm
Weight
39 kg
The Waaree Energies BiN-03-695 is a 695 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| BiN-03-680 | 680 W | 47.78 V | 18.16 A |
| BiN-03-685 | 685 W | 47.98 V | 18.2 A |
| BiN-03-690 | 690 W | 48.18 V | 18.23 A |
| BiN-03-700 | 700 W | 48.58 V | 18.31 A |
| BiN-03-705 | 705 W | 48.77 V | 18.36 A |
| BiN-03-710 | 710 W | 48.97 V | 18.39 A |
| BiN-03-715 | 715 W | 49.17 V | 18.42 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.38 V (within ±5%), and temperature coefficient TcVoc close to -0.26%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Waaree Energies BiN-03-695.