640 W TOPCon solar panel with 132 cells. Voc 49.8 V · Isc 16.32 A · TcVoc -0.24%/°C.
Select the panel you want to replace
200 panels found · 4139 panels excluded
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.62 V | 0.4% |
| Vmpp | 41.8 V | 41.64 V | 0.4% |
| Isc | 16.32 A | 16.25 A | 0.4% |
| Impp | 15.31 A | 15.25 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.98 V | 0.4% |
| Vmpp | 41.8 V | 41.96 V | 0.4% |
| Isc | 16.32 A | 16.39 A | 0.4% |
| Impp | 15.31 A | 15.37 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.9 V | 0.2% |
| Vmpp | 41.8 V | 41.7 V | 0.2% |
| Isc | 16.32 A | 16.06 A | 1.6% |
| Impp | 15.31 A | 14.99 A | 2.1% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.75 V | 0.1% |
| Vmpp | 41.8 V | 41.38 V | 1.0% |
| Isc | 16.32 A | 16.33 A | 0.1% |
| Impp | 15.31 A | 15.47 A | 1.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.75 V | 0.1% |
| Vmpp | 41.8 V | 41.38 V | 1.0% |
| Isc | 16.32 A | 16.33 A | 0.1% |
| Impp | 15.31 A | 15.47 A | 1.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.85 V | 0.1% |
| Vmpp | 41.8 V | 41.51 V | 0.7% |
| Isc | 16.32 A | 16.39 A | 0.4% |
| Impp | 15.31 A | 15.54 A | 1.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.77 V | 0.1% |
| Vmpp | 41.8 V | 41.43 V | 0.9% |
| Isc | 16.32 A | 16.59 A | 1.7% |
| Impp | 15.31 A | 15.69 A | 2.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 50 V | 0.4% |
| Vmpp | 41.8 V | 41.65 V | 0.4% |
| Isc | 16.32 A | 16.45 A | 0.8% |
| Impp | 15.31 A | 15.61 A | 2.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.72 V | 0.2% |
| Vmpp | 41.8 V | 42.11 V | 0.7% |
| Isc | 16.32 A | 16.5 A | 1.1% |
| Impp | 15.31 A | 15.32 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.69 V | 0.2% |
| Vmpp | 41.8 V | 41.45 V | 0.8% |
| Isc | 16.32 A | 16.29 A | 0.2% |
| Impp | 15.31 A | 15.35 A | 0.3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.9 V | 0.2% |
| Vmpp | 41.8 V | 41.48 V | 0.8% |
| Isc | 16.32 A | 16.31 A | 0.1% |
| Impp | 15.31 A | 15.43 A | 0.8% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.8 V | 49.69 V | 0.2% |
| Vmpp | 41.8 V | 41.45 V | 0.8% |
| Isc | 16.32 A | 16.29 A | 0.2% |
| Impp | 15.31 A | 15.35 A | 0.3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.8 V
Vmpp
41.8 V
Isc
16.32 A
Impp
15.31 A
TcVoc
-0.24 %/°C
TcPmax
-0.29 %/°C
Pmax
640 W
Cells
132
Bifaciality
80%
Length
2384 mm
Width
1303 mm
Thickness
33 mm
Weight
37 kg
The Yingli Solar YL640CF66 i/2 is a 640 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| YL620CF66 i/2 | 620 W | 49.08 V | 16.04 A |
| YL625CF66 i/2 | 625 W | 49.26 V | 16.11 A |
| YL630CF66 i/2 | 630 W | 49.44 V | 16.18 A |
| YL635CF66 i/2 | 635 W | 49.62 V | 16.25 A |
| YL645CF66 i/2 | 645 W | 49.98 V | 16.39 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.8 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Yingli Solar YL640CF66 i/2.