670 W PERC solar panel with 132 cells. Voc 46.1 V · Isc 18.58 A · TcVoc -0.25%/°C.
Select the panel you want to replace
18 panels found · 4321 panels excluded
665 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.9 V | 0.4% |
| Vmpp | 38.3 V | 38.1 V | 0.5% |
| Isc | 18.58 A | 18.54 A | 0.2% |
| Impp | 17.5 A | 17.46 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
675 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 46 V | 0.2% |
| Vmpp | 38.3 V | 38.9 V | 1.6% |
| Isc | 18.58 A | 18.59 A | 0.1% |
| Impp | 17.5 A | 17.36 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
660 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.7 V | 0.9% |
| Vmpp | 38.3 V | 37.9 V | 1.0% |
| Isc | 18.58 A | 18.48 A | 0.5% |
| Impp | 17.5 A | 17.42 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
670 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.8 V | 0.7% |
| Vmpp | 38.3 V | 38.7 V | 1.0% |
| Isc | 18.58 A | 18.55 A | 0.2% |
| Impp | 17.5 A | 17.32 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
665 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.6 V | 1.1% |
| Vmpp | 38.3 V | 38.5 V | 0.5% |
| Isc | 18.58 A | 18.51 A | 0.4% |
| Impp | 17.5 A | 17.28 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
655 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.5 V | 1.3% |
| Vmpp | 38.3 V | 37.7 V | 1.6% |
| Isc | 18.58 A | 18.42 A | 0.9% |
| Impp | 17.5 A | 17.38 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
665 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 46.18 V | 0.2% |
| Vmpp | 38.3 V | 38.21 V | 0.2% |
| Isc | 18.58 A | 18.31 A | 1.5% |
| Impp | 17.5 A | 17.4 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.28 %/°C | ±0.030 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
660 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.4 V | 1.5% |
| Vmpp | 38.3 V | 38.3 V | 0.0% |
| Isc | 18.58 A | 18.47 A | 0.6% |
| Impp | 17.5 A | 17.24 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
660 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.98 V | 0.3% |
| Vmpp | 38.3 V | 38.01 V | 0.8% |
| Isc | 18.58 A | 18.26 A | 1.7% |
| Impp | 17.5 A | 17.36 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.28 %/°C | ±0.030 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
670 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.67 V | 0.9% |
| Vmpp | 38.3 V | 38.36 V | 0.2% |
| Isc | 18.58 A | 18.45 A | 0.7% |
| Impp | 17.5 A | 17.47 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.285 %/°C | ±0.035 %/°C |
| TcPmax | -0.34 %/°C | -0.36 %/°C | ±0.020 %/°C |
650 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.3 V | 1.7% |
| Vmpp | 38.3 V | 37.5 V | 2.1% |
| Isc | 18.58 A | 18.36 A | 1.2% |
| Impp | 17.5 A | 17.34 A | 0.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
655 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.1 V | 45.2 V | 2.0% |
| Vmpp | 38.3 V | 38.1 V | 0.5% |
| Isc | 18.58 A | 18.43 A | 0.8% |
| Impp | 17.5 A | 17.2 A | 1.7% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.34 %/°C | -0.34 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
46.1 V
Vmpp
38.3 V
Isc
18.58 A
Impp
17.5 A
TcVoc
-0.25 %/°C
TcPmax
-0.34 %/°C
Pmax
670 W
Cells
132
Length
2384 mm
Width
1303 mm
Thickness
35 mm
Weight
34 kg
The Yingli Solar YL670D-66f 1/2 is a 670 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| YL645D-66f 1/2 | 645 W | 45.1 V | 18.31 A |
| YL650D-66f 1/2 | 650 W | 45.3 V | 18.36 A |
| YL655D-66f 1/2 | 655 W | 45.5 V | 18.42 A |
| YL660D-66f 1/2 | 660 W | 45.7 V | 18.48 A |
| YL665D-66f 1/2 | 665 W | 45.9 V | 18.54 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 46.1 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Yingli Solar YL670D-66f 1/2.