730 W TOPCon solar panel with 132 cells. Voc 49.5 V · Isc 18.49 A · TcVoc -0.24%/°C.
Select the panel you want to replace
132 panels found · 3568 panels excluded
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.5 V | 0.0% |
| Vmpp | 41.7 V | 41.58 V | 0.3% |
| Isc | 18.49 A | 18.59 A | 0.5% |
| Impp | 17.51 A | 17.68 A | 1.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.6 V | 0.2% |
| Vmpp | 41.7 V | 41.5 V | 0.5% |
| Isc | 18.49 A | 18.54 A | 0.3% |
| Impp | 17.51 A | 17.47 A | 0.2% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.4 V | 0.2% |
| Vmpp | 41.7 V | 41.3 V | 1.0% |
| Isc | 18.49 A | 18.49 A | 0.0% |
| Impp | 17.51 A | 17.44 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.4 V | 0.2% |
| Vmpp | 41.7 V | 41.3 V | 1.0% |
| Isc | 18.49 A | 18.49 A | 0.0% |
| Impp | 17.51 A | 17.44 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.3 V | 0.4% |
| Vmpp | 41.7 V | 41.5 V | 0.5% |
| Isc | 18.49 A | 18.46 A | 0.2% |
| Impp | 17.51 A | 17.47 A | 0.2% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.3 V | 0.4% |
| Vmpp | 41.7 V | 41.41 V | 0.7% |
| Isc | 18.49 A | 18.55 A | 0.3% |
| Impp | 17.51 A | 17.63 A | 0.7% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.55 V | 0.1% |
| Vmpp | 41.7 V | 41.37 V | 0.8% |
| Isc | 18.49 A | 18.68 A | 1.0% |
| Impp | 17.51 A | 17.65 A | 0.8% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.45 V | 0.1% |
| Vmpp | 41.7 V | 41.2 V | 1.2% |
| Isc | 18.49 A | 18.6 A | 0.6% |
| Impp | 17.51 A | 17.6 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.65 V | 0.3% |
| Vmpp | 41.7 V | 41.53 V | 0.4% |
| Isc | 18.49 A | 18.75 A | 1.4% |
| Impp | 17.51 A | 17.7 A | 1.1% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.9 V | 0.8% |
| Vmpp | 41.7 V | 41.7 V | 0.0% |
| Isc | 18.49 A | 18.58 A | 0.5% |
| Impp | 17.51 A | 17.51 A | 0.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.56 V | 0.1% |
| Vmpp | 41.7 V | 41.45 V | 0.6% |
| Isc | 18.49 A | 18.7 A | 1.1% |
| Impp | 17.51 A | 17.62 A | 0.6% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.5 V | 49.6 V | 0.2% |
| Vmpp | 41.7 V | 41.5 V | 0.5% |
| Isc | 18.49 A | 18.52 A | 0.2% |
| Impp | 17.51 A | 17.47 A | 0.2% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.5 V
Vmpp
41.7 V
Isc
18.49 A
Impp
17.51 A
TcVoc
-0.24 %/°C
TcPmax
-0.29 %/°C
Pmax
730 W
Cells
132
Bifaciality
80%
Length
2383 mm
Width
1302 mm
Thickness
30 mm
Weight
37 kg
The AE Solar CME-132BDS-730 is a 730 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 710 W | 48.7 V | 18.37 A | |
| 715 W | 48.9 V | 18.4 A | |
| 720 W | 49.1 V | 18.43 A | |
| 725 W | 49.3 V | 18.46 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.5 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original AE Solar CME-132BDS-730.