625 W TOPCon solar panel with 132 cells. Voc 49.9 V · Isc 16.06 A · TcVoc -0.24%/°C.
Select the panel you want to replace
185 panels found · 3515 panels excluded
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.8 V | 0.2% |
| Vmpp | 41.7 V | 41.8 V | 0.2% |
| Isc | 16.06 A | 16.32 A | 1.6% |
| Impp | 14.99 A | 15.31 A | 2.1% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.98 V | 0.2% |
| Vmpp | 41.7 V | 41.96 V | 0.6% |
| Isc | 16.06 A | 16.39 A | 2.1% |
| Impp | 14.99 A | 15.37 A | 2.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.62 V | 0.6% |
| Vmpp | 41.7 V | 41.64 V | 0.1% |
| Isc | 16.06 A | 16.25 A | 1.2% |
| Impp | 14.99 A | 15.25 A | 1.7% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.6 V | 0.6% |
| Vmpp | 41.7 V | 41.4 V | 0.7% |
| Isc | 16.06 A | 16.03 A | 0.2% |
| Impp | 14.99 A | 14.98 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 50.2 V | 0.6% |
| Vmpp | 41.7 V | 42 V | 0.7% |
| Isc | 16.06 A | 16.09 A | 0.2% |
| Impp | 14.99 A | 15 A | 0.1% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.95 V | 0.1% |
| Vmpp | 41.7 V | 41.46 V | 0.6% |
| Isc | 16.06 A | 16.05 A | 0.1% |
| Impp | 14.99 A | 15.2 A | 1.4% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.85 V | 0.1% |
| Vmpp | 41.7 V | 41.51 V | 0.5% |
| Isc | 16.06 A | 16.39 A | 2.1% |
| Impp | 14.99 A | 15.54 A | 3.7% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.9 V | 0.0% |
| Vmpp | 41.7 V | 41.48 V | 0.5% |
| Isc | 16.06 A | 16.31 A | 1.6% |
| Impp | 14.99 A | 15.43 A | 2.9% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.87 V | 0.1% |
| Vmpp | 41.7 V | 41.45 V | 0.6% |
| Isc | 16.06 A | 16.05 A | 0.1% |
| Impp | 14.99 A | 15.2 A | 1.4% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.72 V | 0.4% |
| Vmpp | 41.7 V | 41.51 V | 0.5% |
| Isc | 16.06 A | 16.07 A | 0.1% |
| Impp | 14.99 A | 15.19 A | 1.3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.88 V | 0.0% |
| Vmpp | 41.7 V | 41.3 V | 1.0% |
| Isc | 16.06 A | 16.32 A | 1.6% |
| Impp | 14.99 A | 15.5 A | 3.4% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.9 V | 49.88 V | 0.0% |
| Vmpp | 41.7 V | 41.3 V | 1.0% |
| Isc | 16.06 A | 16.32 A | 1.6% |
| Impp | 14.99 A | 15.5 A | 3.4% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.9 V
Vmpp
41.7 V
Isc
16.06 A
Impp
14.99 A
TcVoc
-0.24 %/°C
TcPmax
-0.29 %/°C
Pmax
625 W
Cells
132
Bifaciality
80%
Length
2383 mm
Width
1133 mm
Thickness
30 mm
Weight
33.7 kg
The AE Solar CMER-132BDS-625 is a 625 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 610 W | 49 V | 15.96 A | |
| 615 W | 49.3 V | 15.99 A | |
| 620 W | 49.6 V | 16.03 A | |
| 630 W | 50.2 V | 16.09 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.9 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original AE Solar CMER-132BDS-625.