465 W ABC solar panel with 96 cells. Voc 34.8 V · Isc 16.33 A · TcVoc -0.22%/°C.
Select the panel you want to replace
67 panels found · 4272 panels excluded
470 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 35 V | 0.6% |
| Vmpp | 30.55 V | 30.74 V | 0.6% |
| Isc | 16.33 A | 16.43 A | 0.6% |
| Impp | 15.22 A | 15.29 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
475 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 35.19 V | 1.1% |
| Vmpp | 30.55 V | 30.9 V | 1.1% |
| Isc | 16.33 A | 16.52 A | 1.2% |
| Impp | 15.22 A | 15.37 A | 1.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
480 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 35.33 V | 1.5% |
| Vmpp | 30.55 V | 31.05 V | 1.6% |
| Isc | 16.33 A | 16.63 A | 1.8% |
| Impp | 15.22 A | 15.46 A | 1.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 34.91 V | 0.3% |
| Vmpp | 30.55 V | 29.98 V | 1.9% |
| Isc | 16.33 A | 15.86 A | 2.9% |
| Impp | 15.22 A | 15.01 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 35.79 V | 2.8% |
| Vmpp | 30.55 V | 30.6 V | 0.2% |
| Isc | 16.33 A | 15.98 A | 2.1% |
| Impp | 15.22 A | 15.2 A | 0.1% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
485 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 35.57 V | 2.2% |
| Vmpp | 30.55 V | 31.19 V | 2.1% |
| Isc | 16.33 A | 16.71 A | 2.3% |
| Impp | 15.22 A | 15.55 A | 2.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 34.71 V | 0.3% |
| Vmpp | 30.55 V | 29.8 V | 2.5% |
| Isc | 16.33 A | 15.79 A | 3.3% |
| Impp | 15.22 A | 14.93 A | 1.9% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 34.85 V | 0.1% |
| Vmpp | 30.55 V | 29.9 V | 2.1% |
| Isc | 16.33 A | 16 A | 2.0% |
| Impp | 15.22 A | 14.89 A | 2.2% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.3 %/°C | ±0.040 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 34.85 V | 0.1% |
| Vmpp | 30.55 V | 29.9 V | 2.1% |
| Isc | 16.33 A | 16 A | 2.0% |
| Impp | 15.22 A | 14.89 A | 2.2% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.3 %/°C | ±0.040 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 35.11 V | 0.9% |
| Vmpp | 30.55 V | 30.16 V | 1.3% |
| Isc | 16.33 A | 15.93 A | 2.4% |
| Impp | 15.22 A | 15.09 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
445 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 34.98 V | 0.5% |
| Vmpp | 30.55 V | 28.89 V | 5.4% |
| Isc | 16.33 A | 16.11 A | 1.3% |
| Impp | 15.22 A | 15.41 A | 1.2% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 34.8 V | 34.8 V | 0.0% |
| Vmpp | 30.55 V | 29.48 V | 3.5% |
| Isc | 16.33 A | 15.9 A | 2.6% |
| Impp | 15.22 A | 15.09 A | 0.9% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
34.8 V
Vmpp
30.55 V
Isc
16.33 A
Impp
15.22 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
465 W
Cells
96
Bifaciality
80%
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
24.1 kg
The Aiko Solar AIKO-A465-GRH48Dw is a 465 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AIKO-A470-GRH48Dw | 470 W | 35 V | 16.43 A |
| AIKO-A475-GRH48Dw | 475 W | 35.19 V | 16.52 A |
| AIKO-A480-GRH48Dw | 480 W | 35.33 V | 16.63 A |
| AIKO-A485-GRH48Dw | 485 W | 35.57 V | 16.71 A |
| AIKO-A490-GRH48Dw | 490 W | 35.72 V | 16.79 A |
| AIKO-A495-GRH48Dw | 495 W | 35.86 V | 16.9 A |
The most critical specs to match are: cell count (must be exactly 96), Voc close to 34.8 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Aiko Solar AIKO-A465-GRH48Dw.