485 W ABC solar panel with 96 cells. Voc 35.57 V · Isc 16.71 A · TcVoc -0.22%/°C.
Select the panel you want to replace
48 panels found · 4291 panels excluded
490 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.72 V | 0.4% |
| Vmpp | 31.19 V | 31.35 V | 0.5% |
| Isc | 16.71 A | 16.79 A | 0.5% |
| Impp | 15.55 A | 15.63 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
480 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.33 V | 0.7% |
| Vmpp | 31.19 V | 31.05 V | 0.4% |
| Isc | 16.71 A | 16.63 A | 0.5% |
| Impp | 15.55 A | 15.46 A | 0.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.86 V | 0.8% |
| Vmpp | 31.19 V | 31.51 V | 1.0% |
| Isc | 16.71 A | 16.9 A | 1.1% |
| Impp | 15.55 A | 15.71 A | 1.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
475 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.19 V | 1.1% |
| Vmpp | 31.19 V | 30.9 V | 0.9% |
| Isc | 16.71 A | 16.52 A | 1.1% |
| Impp | 15.55 A | 15.37 A | 1.2% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
470 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35 V | 1.6% |
| Vmpp | 31.19 V | 30.74 V | 1.4% |
| Isc | 16.71 A | 16.43 A | 1.7% |
| Impp | 15.55 A | 15.29 A | 1.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.79 V | 0.6% |
| Vmpp | 31.19 V | 30.6 V | 1.9% |
| Isc | 16.71 A | 15.98 A | 4.4% |
| Impp | 15.55 A | 15.2 A | 2.3% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.9 V | 0.9% |
| Vmpp | 31.19 V | 30.79 V | 1.3% |
| Isc | 16.71 A | 15.93 A | 4.7% |
| Impp | 15.55 A | 15.27 A | 1.8% |
| TcVoc | -0.22 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.28 %/°C | ±0.020 %/°C |
475 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.6 V | 0.1% |
| Vmpp | 31.19 V | 30.4 V | 2.5% |
| Isc | 16.71 A | 16.26 A | 2.7% |
| Impp | 15.55 A | 15.63 A | 0.5% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
465 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 34.8 V | 2.2% |
| Vmpp | 31.19 V | 30.55 V | 2.1% |
| Isc | 16.71 A | 16.33 A | 2.3% |
| Impp | 15.55 A | 15.22 A | 2.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
480 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.7 V | 0.4% |
| Vmpp | 31.19 V | 30.5 V | 2.2% |
| Isc | 16.71 A | 16.3 A | 2.5% |
| Impp | 15.55 A | 15.74 A | 1.2% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.5 V | 0.2% |
| Vmpp | 31.19 V | 30.3 V | 2.9% |
| Isc | 16.71 A | 16.22 A | 2.9% |
| Impp | 15.55 A | 15.51 A | 0.3% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
485 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.57 V | 35.8 V | 0.6% |
| Vmpp | 31.19 V | 30.6 V | 1.9% |
| Isc | 16.71 A | 16.34 A | 2.2% |
| Impp | 15.55 A | 15.85 A | 1.9% |
| TcVoc | -0.22 %/°C | -0.25 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
35.57 V
Vmpp
31.19 V
Isc
16.71 A
Impp
15.55 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
485 W
Cells
96
Bifaciality
80%
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
24.1 kg
The Aiko Solar AIKO-A485-GRH48Dw is a 485 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AIKO-A465-GRH48Dw | 465 W | 34.8 V | 16.33 A |
| AIKO-A470-GRH48Dw | 470 W | 35 V | 16.43 A |
| AIKO-A475-GRH48Dw | 475 W | 35.19 V | 16.52 A |
| AIKO-A480-GRH48Dw | 480 W | 35.33 V | 16.63 A |
| AIKO-A490-GRH48Dw | 490 W | 35.72 V | 16.79 A |
| AIKO-A495-GRH48Dw | 495 W | 35.86 V | 16.9 A |
The most critical specs to match are: cell count (must be exactly 96), Voc close to 35.57 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Aiko Solar AIKO-A485-GRH48Dw.