505 W ABC solar panel with 108 cells. Voc 40.96 V · Isc 15.45 A · TcVoc -0.22%/°C.
Select the panel you want to replace
94 panels found · 3616 panels excluded
505 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.96 V | 0.0% |
| Vmpp | 34.47 V | 34.47 V | 0.0% |
| Isc | 15.45 A | 15.45 A | 0.0% |
| Impp | 14.66 A | 14.66 A | 0.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
510 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 41.11 V | 0.4% |
| Vmpp | 34.47 V | 34.57 V | 0.3% |
| Isc | 15.45 A | 15.52 A | 0.5% |
| Impp | 14.66 A | 14.76 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
500 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.81 V | 0.4% |
| Vmpp | 34.47 V | 34.37 V | 0.3% |
| Isc | 15.45 A | 15.39 A | 0.4% |
| Impp | 14.66 A | 14.55 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
500 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.81 V | 0.4% |
| Vmpp | 34.47 V | 34.37 V | 0.3% |
| Isc | 15.45 A | 15.39 A | 0.4% |
| Impp | 14.66 A | 14.55 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
500 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.81 V | 0.4% |
| Vmpp | 34.47 V | 34.37 V | 0.3% |
| Isc | 15.45 A | 15.39 A | 0.4% |
| Impp | 14.66 A | 14.55 A | 0.8% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.71 V | 0.6% |
| Vmpp | 34.47 V | 34.27 V | 0.6% |
| Isc | 15.45 A | 15.33 A | 0.8% |
| Impp | 14.66 A | 14.45 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.71 V | 0.6% |
| Vmpp | 34.47 V | 34.27 V | 0.6% |
| Isc | 15.45 A | 15.33 A | 0.8% |
| Impp | 14.66 A | 14.45 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.71 V | 0.6% |
| Vmpp | 34.47 V | 34.27 V | 0.6% |
| Isc | 15.45 A | 15.33 A | 0.8% |
| Impp | 14.66 A | 14.45 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
495 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.71 V | 0.6% |
| Vmpp | 34.47 V | 34.27 V | 0.6% |
| Isc | 15.45 A | 15.33 A | 0.8% |
| Impp | 14.66 A | 14.45 A | 1.4% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.61 V | 0.9% |
| Vmpp | 34.47 V | 34.17 V | 0.9% |
| Isc | 15.45 A | 15.27 A | 1.2% |
| Impp | 14.66 A | 14.35 A | 2.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.61 V | 0.9% |
| Vmpp | 34.47 V | 34.17 V | 0.9% |
| Isc | 15.45 A | 15.27 A | 1.2% |
| Impp | 14.66 A | 14.35 A | 2.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
490 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 40.96 V | 40.61 V | 0.9% |
| Vmpp | 34.47 V | 34.17 V | 0.9% |
| Isc | 15.45 A | 15.27 A | 1.2% |
| Impp | 14.66 A | 14.35 A | 2.1% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
40.96 V
Vmpp
34.47 V
Isc
15.45 A
Impp
14.66 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
505 W
Cells
108
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
21.1 kg
The Aiko Solar AIKO-A505-MCE54Mw is a 505 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AIKO-A470-MCE54Mw | 470 W | 40.7 V | 14.72 A |
| AIKO-A475-MCE54Mw | 475 W | 40.8 V | 14.76 A |
| AIKO-A480-MCE54Mw | 480 W | 40.9 V | 14.8 A |
| AIKO-A485-MCE54Mw | 485 W | 40.51 V | 15.21 A |
| AIKO-A490-MCE54Mw | 490 W | 40.61 V | 15.27 A |
| AIKO-A495-MCE54Mw | 495 W | 40.71 V | 15.33 A |
| AIKO-A500-MCE54Mw | 500 W | 40.81 V | 15.39 A |
| AIKO-A510-MCE54Mw | 510 W | 41.11 V | 15.52 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 40.96 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Aiko Solar AIKO-A505-MCE54Mw.