565 W ABC solar panel with 120 cells. Voc 45.68 V · Isc 15.44 A · TcVoc -0.22%/°C.
Select the panel you want to replace
18 panels found · 3692 panels excluded
560 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.53 V | 0.3% |
| Vmpp | 38.49 V | 38.39 V | 0.3% |
| Isc | 15.44 A | 15.37 A | 0.5% |
| Impp | 14.69 A | 14.59 A | 0.7% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
545 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.7 V | 0.0% |
| Vmpp | 38.49 V | 38.5 V | 0.0% |
| Isc | 15.44 A | 14.88 A | 3.6% |
| Impp | 14.69 A | 14.16 A | 3.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
545 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.7 V | 0.0% |
| Vmpp | 38.49 V | 38.5 V | 0.0% |
| Isc | 15.44 A | 14.88 A | 3.6% |
| Impp | 14.69 A | 14.16 A | 3.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
555 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.38 V | 0.7% |
| Vmpp | 38.49 V | 38.29 V | 0.5% |
| Isc | 15.44 A | 15.31 A | 0.8% |
| Impp | 14.69 A | 14.5 A | 1.3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
550 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.8 V | 0.3% |
| Vmpp | 38.49 V | 38.6 V | 0.3% |
| Isc | 15.44 A | 14.92 A | 3.4% |
| Impp | 14.69 A | 14.25 A | 3.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
550 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.8 V | 0.3% |
| Vmpp | 38.49 V | 38.6 V | 0.3% |
| Isc | 15.44 A | 14.92 A | 3.4% |
| Impp | 14.69 A | 14.25 A | 3.0% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
555 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.9 V | 0.5% |
| Vmpp | 38.49 V | 38.7 V | 0.5% |
| Isc | 15.44 A | 14.96 A | 3.1% |
| Impp | 14.69 A | 14.35 A | 2.3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
555 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.9 V | 0.5% |
| Vmpp | 38.49 V | 38.7 V | 0.5% |
| Isc | 15.44 A | 14.96 A | 3.1% |
| Impp | 14.69 A | 14.35 A | 2.3% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
550 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.28 V | 0.9% |
| Vmpp | 38.49 V | 38.19 V | 0.8% |
| Isc | 15.44 A | 15.25 A | 1.2% |
| Impp | 14.69 A | 14.41 A | 1.9% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
545 W
ABC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.18 V | 1.1% |
| Vmpp | 38.49 V | 38.09 V | 1.0% |
| Isc | 15.44 A | 15.19 A | 1.6% |
| Impp | 14.69 A | 14.31 A | 2.6% |
| TcVoc | -0.22 %/°C | -0.22 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
560 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.28 V | 0.9% |
| Vmpp | 38.49 V | 37.51 V | 2.5% |
| Isc | 15.44 A | 15.65 A | 1.4% |
| Impp | 14.69 A | 14.93 A | 1.6% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
560 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 45.68 V | 45.28 V | 0.9% |
| Vmpp | 38.49 V | 37.51 V | 2.5% |
| Isc | 15.44 A | 15.65 A | 1.4% |
| Impp | 14.69 A | 14.93 A | 1.6% |
| TcVoc | -0.22 %/°C | -0.2 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
45.68 V
Vmpp
38.49 V
Isc
15.44 A
Impp
14.69 A
TcVoc
-0.22 %/°C
TcPmax
-0.26 %/°C
Pmax
565 W
Cells
120
Length
1954 mm
Width
1134 mm
Thickness
30 mm
Weight
27.1 kg
The Aiko Solar AIKO-A565-MCE60Dw is a 565 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AIKO-A530-MCE60Dw | 530 W | 45.4 V | 14.76 A |
| AIKO-A535-MCE60Dw | 535 W | 45.5 V | 14.8 A |
| AIKO-A540-MCE60Dw | 540 W | 45.08 V | 15.13 A |
| AIKO-A545-MCE60Dw | 545 W | 45.18 V | 15.19 A |
| AIKO-A550-MCE60Dw | 550 W | 45.28 V | 15.25 A |
| AIKO-A555-MCE60Dw | 555 W | 45.38 V | 15.31 A |
| AIKO-A560-MCE60Dw | 560 W | 45.53 V | 15.37 A |
The most critical specs to match are: cell count (must be exactly 120), Voc close to 45.68 V (within ±5%), and temperature coefficient TcVoc close to -0.22%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Aiko Solar AIKO-A565-MCE60Dw.