420 W TOPCon solar panel with 108 cells. Voc 39.19 V · Isc 13.19 A · TcVoc -0.24%/°C.
Select the panel you want to replace
93 panels found · 3418 panels excluded
420 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.19 V | 0.0% |
| Vmpp | 33.52 V | 33.52 V | 0.0% |
| Isc | 13.19 A | 13.19 A | 0.0% |
| Impp | 12.53 A | 12.53 A | 0.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.38 V | 0.5% |
| Vmpp | 33.52 V | 33.71 V | 0.6% |
| Isc | 13.19 A | 13.27 A | 0.6% |
| Impp | 12.53 A | 12.61 A | 0.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.38 V | 0.5% |
| Vmpp | 33.52 V | 33.71 V | 0.6% |
| Isc | 13.19 A | 13.27 A | 0.6% |
| Impp | 12.53 A | 12.61 A | 0.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
430 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.22 V | 0.1% |
| Vmpp | 33.52 V | 33.2 V | 1.0% |
| Isc | 13.19 A | 13.63 A | 3.3% |
| Impp | 12.53 A | 12.95 A | 3.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
435 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.41 V | 0.6% |
| Vmpp | 33.52 V | 33.38 V | 0.4% |
| Isc | 13.19 A | 13.71 A | 3.9% |
| Impp | 12.53 A | 13.03 A | 4.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
430 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.57 V | 1.0% |
| Vmpp | 33.52 V | 33.89 V | 1.1% |
| Isc | 13.19 A | 13.35 A | 1.2% |
| Impp | 12.53 A | 12.69 A | 1.3% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
430 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.57 V | 1.0% |
| Vmpp | 33.52 V | 33.89 V | 1.1% |
| Isc | 13.19 A | 13.35 A | 1.2% |
| Impp | 12.53 A | 12.69 A | 1.3% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.6 V | 1.0% |
| Vmpp | 33.52 V | 33.56 V | 0.1% |
| Isc | 13.19 A | 13.79 A | 4.5% |
| Impp | 12.53 A | 13.11 A | 4.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.31 %/°C | ±0.000 %/°C |
430 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.32 V | 0.3% |
| Vmpp | 33.52 V | 32.94 V | 1.7% |
| Isc | 13.19 A | 13.74 A | 4.2% |
| Impp | 12.53 A | 13.05 A | 4.2% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
425 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.03 V | 0.4% |
| Vmpp | 33.52 V | 32.74 V | 2.3% |
| Isc | 13.19 A | 13.66 A | 3.6% |
| Impp | 12.53 A | 12.98 A | 3.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
425 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.45 V | 0.7% |
| Vmpp | 33.52 V | 33.27 V | 0.7% |
| Isc | 13.19 A | 13.61 A | 3.2% |
| Impp | 12.53 A | 12.78 A | 2.0% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
420 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.19 V | 39.45 V | 0.7% |
| Vmpp | 33.52 V | 33.07 V | 1.3% |
| Isc | 13.19 A | 13.54 A | 2.7% |
| Impp | 12.53 A | 12.71 A | 1.4% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.31 %/°C | -0.29 %/°C | ±0.020 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
39.19 V
Vmpp
33.52 V
Isc
13.19 A
Impp
12.53 A
TcVoc
-0.24 %/°C
TcPmax
-0.31 %/°C
Pmax
420 W
Cells
108
Length
1752 mm
Width
1144 mm
Thickness
40 mm
Weight
22 kg
The aleo solar L84S420 is a 420 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 425 W | 39.38 V | 13.27 A | |
| 430 W | 39.57 V | 13.35 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 39.19 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original aleo solar L84S420.