560 W TOPCon solar panel with 144 cells. Voc 50.4 V · Isc 14.04 A · TcVoc -0.25%/°C.
Select the panel you want to replace
103 panels found · 4236 panels excluded
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.47 V | 0.1% |
| Vmpp | 42.2 V | 41.77 V | 1.0% |
| Isc | 14.04 A | 14.15 A | 0.8% |
| Impp | 13.28 A | 13.41 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
555 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.34 V | 0.1% |
| Vmpp | 42.2 V | 41.64 V | 1.3% |
| Isc | 14.04 A | 14.07 A | 0.2% |
| Impp | 13.28 A | 13.33 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.6 V | 0.4% |
| Vmpp | 42.2 V | 42.4 V | 0.5% |
| Isc | 14.04 A | 14.09 A | 0.4% |
| Impp | 13.28 A | 13.33 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.6 V | 0.4% |
| Vmpp | 42.2 V | 41.92 V | 0.7% |
| Isc | 14.04 A | 14.23 A | 1.4% |
| Impp | 13.28 A | 13.48 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.74 V | 0.7% |
| Vmpp | 42.2 V | 42.07 V | 0.3% |
| Isc | 14.04 A | 14.31 A | 1.9% |
| Impp | 13.28 A | 13.55 A | 2.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.8 V | 0.8% |
| Vmpp | 42.2 V | 42.6 V | 0.9% |
| Isc | 14.04 A | 14.14 A | 0.7% |
| Impp | 13.28 A | 13.39 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
560 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.5 V | 0.2% |
| Vmpp | 42.2 V | 42.1 V | 0.2% |
| Isc | 14.04 A | 14.11 A | 0.5% |
| Impp | 13.28 A | 13.3 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 51 V | 1.2% |
| Vmpp | 42.2 V | 42.8 V | 1.4% |
| Isc | 14.04 A | 14.19 A | 1.1% |
| Impp | 13.28 A | 13.44 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
565 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.3 V | 0.2% |
| Vmpp | 42.2 V | 42.42 V | 0.5% |
| Isc | 14.04 A | 14.16 A | 0.9% |
| Impp | 13.28 A | 13.32 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.265 %/°C | ±0.015 %/°C |
| TcPmax | -0.3 %/°C | -0.34 %/°C | ±0.040 %/°C |
550 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.4 V | 0.0% |
| Vmpp | 42.2 V | 42.3 V | 0.2% |
| Isc | 14.04 A | 13.8 A | 1.7% |
| Impp | 13.28 A | 13 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.268 %/°C | ±0.018 %/°C |
| TcPmax | -0.3 %/°C | -0.34 %/°C | ±0.040 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 51.02 V | 1.2% |
| Vmpp | 42.2 V | 42.37 V | 0.4% |
| Isc | 14.04 A | 14.47 A | 3.1% |
| Impp | 13.28 A | 13.69 A | 3.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
560 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.4 V | 50.1 V | 0.6% |
| Vmpp | 42.2 V | 42.25 V | 0.1% |
| Isc | 14.04 A | 14.1 A | 0.4% |
| Impp | 13.28 A | 13.26 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.265 %/°C | ±0.015 %/°C |
| TcPmax | -0.3 %/°C | -0.34 %/°C | ±0.040 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
50.4 V
Vmpp
42.2 V
Isc
14.04 A
Impp
13.28 A
TcVoc
-0.25 %/°C
TcPmax
-0.3 %/°C
Pmax
560 W
Cells
144
Length
2279 mm
Width
1134 mm
Thickness
30 mm
Weight
27.5 kg
The Amerisolar AS-7M144N-HC-560 is a 560 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| AS-7M144N-HC-565 | 565 W | 50.6 V | 14.09 A |
| AS-7M144N-HC-570 | 570 W | 50.8 V | 14.14 A |
| AS-7M144N-HC-575 | 575 W | 51 V | 14.19 A |
| AS-7M144N-HC-580 | 580 W | 51.2 V | 14.24 A |
| AS-7M144N-HC-585 | 585 W | 51.4 V | 14.29 A |
| AS-7M144N-HC-590 | 590 W | 51.6 V | 14.34 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 50.4 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Amerisolar AS-7M144N-HC-560.