Solar Stack
Solar Stack
How it worksGuidesAdd Equipment
Sign in
Solar Stack

Free solar panel & inverter compatibility checker. Verify your PV string configuration is safe before installation.

Tools

  • Calculator
  • Panel Matcher
  • Inverter Finder
  • Inverter Compare
  • Panel Replacement
  • Cable sizing

Resources

  • Guides
  • How it works
  • Standards & Compliance
  • Data API
  • Replacement methodology
  • Add Equipment
  • Feedback

Legal

  • About
  • Privacy Policy
  • Terms of Service
  • Cookie Policy

© 2026 Solar Stack

All replacements

Find replacement for Amerisolar AS-7M144N-HC-570

570 W TOPCon solar panel with 144 cells. Voc 50.8 V · Isc 14.14 A · TcVoc -0.25%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

105 panels found · 4234 panels excluded

Amerisolar AS-7M144N-HC-565

565 W

TOPCon
92Good match
ParameterOriginalReplacementDeviation
Voc50.8 V50.6 V0.4%
Vmpp42.6 V42.4 V0.5%
Isc14.14 A14.09 A0.4%
Impp13.39 A13.33 A0.4%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
Amerisolar AS-7M144N-HC-575

575 W

TOPCon
92Good match
ParameterOriginalReplacementDeviation
Voc50.8 V51 V0.4%
Vmpp42.6 V42.8 V0.5%
Isc14.14 A14.19 A0.4%
Impp13.39 A13.44 A0.4%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
LogicPower LP-570M

570 W

TOPCon
90Good match
ParameterOriginalReplacementDeviation
Voc50.8 V50.74 V0.1%
Vmpp42.6 V42.07 V1.2%
Isc14.14 A14.31 A1.2%
Impp13.39 A13.55 A1.2%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
LogicPower LP-565M

565 W

TOPCon
86Good match
ParameterOriginalReplacementDeviation
Voc50.8 V50.6 V0.4%
Vmpp42.6 V41.92 V1.6%
Isc14.14 A14.23 A0.6%
Impp13.39 A13.48 A0.7%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
LogicPower LP-580M

580 W

TOPCon
86Good match
ParameterOriginalReplacementDeviation
Voc50.8 V51.02 V0.4%
Vmpp42.6 V42.37 V0.5%
Isc14.14 A14.47 A2.3%
Impp13.39 A13.69 A2.2%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
Amerisolar AS-7M144N-HC-560

560 W

TOPCon
84Good match
ParameterOriginalReplacementDeviation
Voc50.8 V50.4 V0.8%
Vmpp42.6 V42.2 V0.9%
Isc14.14 A14.04 A0.7%
Impp13.39 A13.28 A0.8%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
Amerisolar AS-7M144N-HC-580

580 W

TOPCon
84Good match
ParameterOriginalReplacementDeviation
Voc50.8 V51.2 V0.8%
Vmpp42.6 V43 V0.9%
Isc14.14 A14.24 A0.7%
Impp13.39 A13.49 A0.7%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
LogicPower LP-560M

560 W

TOPCon
83Good match
ParameterOriginalReplacementDeviation
Voc50.8 V50.47 V0.6%
Vmpp42.6 V41.77 V1.9%
Isc14.14 A14.15 A0.1%
Impp13.39 A13.41 A0.1%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
LogicPower LP-585M

585 W

TOPCon
83Good match
ParameterOriginalReplacementDeviation
Voc50.8 V51.16 V0.7%
Vmpp42.6 V42.52 V0.2%
Isc14.14 A14.55 A2.9%
Impp13.39 A13.76 A2.8%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C
Ulica Solar UL-570M-144AHVN

570 W

TOPCon
82Good match
ParameterOriginalReplacementDeviation
Voc50.8 V51.14 V0.7%
Vmpp42.6 V42.93 V0.8%
Isc14.14 A13.89 A1.8%
Impp13.39 A13.28 A0.8%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.29 %/°C±0.010 %/°C
Sun Earth DXM8-72H 570W

570 W

TOPCon
80Good match
ParameterOriginalReplacementDeviation
Voc50.8 V50.9 V0.2%
Vmpp42.6 V42.3 V0.7%
Isc14.14 A14.25 A0.8%
Impp13.39 A13.48 A0.7%
TcVoc-0.25 %/°C-0.23 %/°C±0.020 %/°C
TcPmax-0.3 %/°C-0.29 %/°C±0.010 %/°C
LogicPower LP-555M

555 W

TOPCon
78Acceptable
ParameterOriginalReplacementDeviation
Voc50.8 V50.34 V0.9%
Vmpp42.6 V41.64 V2.3%
Isc14.14 A14.07 A0.5%
Impp13.39 A13.33 A0.4%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.3 %/°C-0.3 %/°C±0.000 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

50.8 V

Vmpp

42.6 V

Isc

14.14 A

Impp

13.39 A

TcVoc

-0.25 %/°C

TcPmax

-0.3 %/°C

Pmax

570 W

Cells

144

Length

2279 mm

Width

1134 mm

Thickness

30 mm

Weight

27.5 kg

The Amerisolar AS-7M144N-HC-570 is a 570 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
AS-7M144N-HC-560560 W50.4 V14.04 A
AS-7M144N-HC-565565 W50.6 V14.09 A
AS-7M144N-HC-575575 W51 V14.19 A
AS-7M144N-HC-580580 W51.2 V14.24 A
AS-7M144N-HC-585585 W51.4 V14.29 A
AS-7M144N-HC-590590 W51.6 V14.34 A

Frequently Asked Questions

What specs must match when replacing the Amerisolar AS-7M144N-HC-570?

The most critical specs to match are: cell count (must be exactly 144), Voc close to 50.8 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Amerisolar AS-7M144N-HC-570?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Amerisolar AS-7M144N-HC-570.