Find replacement for DAH Solar BT-DHN-48Z16/DG-FS-460W

460 W TOPCon solar panel with 96 cells. Voc 36.4 V · Isc 15.76 A · TcVoc -0.25%/°C.

Select the panel you want to replace

Panel not in the catalogue?

297 of the 4,444 panels in the catalogue can replace DAH Solar BT-DHN-48Z16/DG-FS-460W. Before you buy, check your pick in the string calculator with your inverter.

Close or harmlessNoticeableLarge differenceTap or click a difference to see what it means for your string.

Exact match

Near-identical electrics — a drop-in swap for the same string.

Match 95–100 % · 138 models

  • DAH Solar BT-DHN-48Z16/DG-FS(BW)-460W — Open the panel page
    450–460 WTOPCon
    100 %
  • DAH Solar DHN-48Z16/DG-460W — Open the panel page
    435–465 WTOPCon
    100 %
  • DAH Solar DHN-48Z16/DG-FS-460W — Open the panel page
    435–465 WTOPCon
    100 %
  • DAH Solar DHN-48Z16/DG(BB)-460W — Open the panel page
    435–465 WTOPCon
    100 %
  • DAH Solar DHN-48Z16/DG(BW)-460W — Open the panel page
    435–465 WTOPCon
    100 %

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 80–94 % · 148 models

  • Risen RSM96-11-475BNDG — Open the panel page
    435–475 WTOPCon
    94 %
  • WINAICO WST-465NCX48-BW — Open the panel page
    465 WTOPCon
    94 %
  • GCL-NT12R/48GDF 470 — Open the panel page
    460–470 WTOPCon
    93 %
  • DAH Solar HE-DHN-48Z20/DG-FS(BW)-485W — Open the panel page
    465–485 WTOPCon
    93 %
  • TCL Zhonghuan HSM-ND48-DR460 — Open the panel page
    440–460 WTOPCon
    93 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 76–79 % · 11 models

  • LEDVANCE M 445 N 48 RB-BB-F7 — Open the panel page
    440–445 WTOPCon
    79 %
  • DMEGC GH430G12RT-B44HST — Open the panel page
    430 WTOPCon
    78 %
  • LONGi LR8-48HGD-450M — Open the panel page
    440–455 WHPBC
    77 %
  • RECOM RCM-440-RDBHAA — Open the panel page
    440–455 WHJT
    76 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

36.4 V

Vmpp

31 V

Isc

15.76 A

Impp

14.84 A

TcVoc

-0.25 %/°C

TcPmax

-0.29 %/°C

Pmax

460 W

Cells

96

Bifaciality

80%

Length

1762 mm

Width

1134 mm

Thickness

28 mm

Weight

24.3 kg

The DAH Solar BT-DHN-48Z16/DG-FS-460W is a 460 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
BT-DHN-48Z16/DG-FS-450W450 W36 V15.64 A
BT-DHN-48Z16/DG-FS-455W455 W36.2 V15.7 A

Frequently Asked Questions

What specs must match when replacing the DAH Solar BT-DHN-48Z16/DG-FS-460W?

Match the voltage, not the cell count or the wattage. The replacement's open-circuit voltage should be no more than 2 % above 36.4 V and its working voltage within 5 % of the original; its working current should not be more than 3 % lower, because the weakest panel in a string sets the current for all of them. A temperature coefficient closer to zero than -0.25 %/°C is fine — it adds less voltage in frost. The finder above screens the whole catalogue by these rules.

Can I use a higher wattage replacement for the DAH Solar BT-DHN-48Z16/DG-FS-460W?

Yes, if its voltage matches. A higher-wattage panel of the same voltage simply has more current, and a string only carries as much as its weakest panel gives, so the extra goes unused at no risk to the string. Two things to check: its higher short-circuit current against the inverter's rating, and its frame, which is usually larger. The finder shows both; verify the pick in the String Compatibility Calculator with your inverter before installing.

What happens if the replacement panel has different voltage specs?

If its Voc is higher, the string comes closer to the inverter's maximum voltage on frosty mornings, when voltage climbs by the TcVoc coefficient; if its Vmpp is lower, the string can drop out of the inverter's working range (MPPT) on hot days. The finder scores each difference only in the direction that hurts — a lower Voc or a flatter coefficient costs nothing — and ranks candidates by how closely they match the DAH Solar BT-DHN-48Z16/DG-FS-460W.