530 W TOPCon solar panel with 132 cells. Voc 46.66 V · Isc 13.76 A · TcVoc -0.25%/°C.
Select the panel you want to replace
14 panels found · 3686 panels excluded
535 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 46.93 V | 0.6% |
| Vmpp | 40.72 V | 40.92 V | 0.5% |
| Isc | 13.76 A | 13.78 A | 0.1% |
| Impp | 13.03 A | 13.09 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
525 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 46.27 V | 0.8% |
| Vmpp | 40.72 V | 40.52 V | 0.5% |
| Isc | 13.76 A | 13.73 A | 0.2% |
| Impp | 13.03 A | 12.96 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
525 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 46.8 V | 0.3% |
| Vmpp | 40.72 V | 39.7 V | 2.5% |
| Isc | 13.76 A | 14.08 A | 2.3% |
| Impp | 13.03 A | 13.22 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
525 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 46.8 V | 0.3% |
| Vmpp | 40.72 V | 39.7 V | 2.5% |
| Isc | 13.76 A | 14.08 A | 2.3% |
| Impp | 13.03 A | 13.22 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
525 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 46.8 V | 0.3% |
| Vmpp | 40.72 V | 39.7 V | 2.5% |
| Isc | 13.76 A | 14.08 A | 2.3% |
| Impp | 13.03 A | 13.22 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
520 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 46.07 V | 1.3% |
| Vmpp | 40.72 V | 40.26 V | 1.1% |
| Isc | 13.76 A | 13.71 A | 0.4% |
| Impp | 13.03 A | 12.94 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
530 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 47.27 V | 1.3% |
| Vmpp | 40.72 V | 40.16 V | 1.4% |
| Isc | 13.76 A | 13.89 A | 0.9% |
| Impp | 13.03 A | 13.2 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 47.3 V | 1.4% |
| Vmpp | 40.72 V | 41.73 V | 2.5% |
| Isc | 13.76 A | 13.67 A | 0.7% |
| Impp | 13.03 A | 12.98 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
540 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 47.63 V | 2.1% |
| Vmpp | 40.72 V | 40.79 V | 0.2% |
| Isc | 13.76 A | 14.01 A | 1.8% |
| Impp | 13.03 A | 13.24 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
535 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 48.04 V | 3.0% |
| Vmpp | 40.72 V | 40.44 V | 0.7% |
| Isc | 13.76 A | 14.29 A | 3.9% |
| Impp | 13.03 A | 13.23 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
530 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 47.81 V | 2.5% |
| Vmpp | 40.72 V | 40.24 V | 1.2% |
| Isc | 13.76 A | 14.22 A | 3.3% |
| Impp | 13.03 A | 13.17 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
550 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 46.66 V | 47.55 V | 1.9% |
| Vmpp | 40.72 V | 40.33 V | 1.0% |
| Isc | 13.76 A | 14.52 A | 5.5% |
| Impp | 13.03 A | 13.64 A | 4.7% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
46.66 V
Vmpp
40.72 V
Isc
13.76 A
Impp
13.03 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
530 W
Cells
132
Bifaciality
80%
Length
2094 mm
Width
1134 mm
Thickness
30 mm
Weight
30 kg
The Eco Green Energy EGE-530W-132N(GM10) is a 530 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 520 W | 46.07 V | 13.71 A | |
| 525 W | 46.27 V | 13.73 A | |
| 535 W | 46.93 V | 13.78 A | |
| 540 W | 47.3 V | 13.67 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 46.66 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Eco Green Energy EGE-530W-132N(GM10).