Solar Stack
Solar Stack
How it worksGuidesAdd Equipment
Sign in
Solar Stack

Free solar panel & inverter compatibility checker. Verify your PV string configuration is safe before installation.

Tools

  • Calculator
  • Panel Matcher
  • Inverter Finder
  • Inverter Compare
  • Panel Replacement
  • Cable sizing

Resources

  • Guides
  • How it works
  • Standards & Compliance
  • Data API
  • Replacement methodology
  • Add Equipment
  • Feedback

Legal

  • About
  • Support
  • Privacy Policy
  • Terms of Service
  • Cookie Policy

© 2026 Solar Stack

All replacements

Find replacement for Hanersun HN18N-54H425W

425 W TOPCon solar panel with 108 cells. Voc 38.1 V · Isc 14.05 A · TcVoc -0.23%/°C.

Select the panel you want to replace

Panel not in the catalogue?

123 of the 4,444 panels in the catalogue can replace Hanersun HN18N-54H425W. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 82–89 % · 6 models

  • Hanersun HN18N-54H420W — Open the panel page
    420 WTOPConsame series
    89 %
  • Hanersun HN18N-54H430W — Open the panel page
    430 WTOPConsame series
    89 %
  • Jolywood JW-HT108N-425 — Open the panel page
    425 WTOPCon
    85 %
  • Astronergy CHSM54N-HC425 — Open the panel page
    425 WTOPCon
    83 %
  • Sun Earth DXM8-54H 420W — Open the panel page
    420 WTOPCon
    83 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 60–79 % · 48 models

  • Hanersun HN18N-54H435W — Open the panel page
    435 WTOPConsame series
    79 %
  • RECOM RCM-440-7NG — Open the panel page
    440 WTOPCon
    79 %
  • TommaTech TT425-108TNFB10 Dark Series — Open the panel page
    425 WTOPCon
    79 %
  • JinkoSolar JKM420N-54HL4-(V) — Open the panel page
    420 WTOPCon
    78 %
  • LogicPower LP-420M — Open the panel page
    420 WTOPCon
    76 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 27–59 % · 69 models

  • Hanersun HN18N-54H445W — Open the panel page
    445 WTOPConsame series
    59 %
  • LONGi LR5-54HTB-420M — Open the panel page
    420 WHPBC
    59 %
  • Perlight Solar PLM-415H8NB-108 — Open the panel page
    415 WTOPCon
    59 %
  • TommaTech TT415-108TNFB10 Dark Series — Open the panel page
    415 WTOPCon
    59 %
  • Canadian Solar CS6R-430T — Open the panel page
    430 WTOPCon
    58 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

38.1 V

Vmpp

32.1 V

Isc

14.05 A

Impp

13.24 A

TcVoc

-0.23 %/°C

TcPmax

-0.28 %/°C

Pmax

425 W

Cells

108

Length

1722 mm

Width

1134 mm

Thickness

30 mm

Weight

20.2 kg

The Hanersun HN18N-54H425W is a 425 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
HN18N-54H420W420 W37.9 V13.98 A
HN18N-54H430W430 W38.3 V14.12 A
HN18N-54H435W435 W38.5 V14.19 A
HN18N-54H440W440 W38.7 V14.26 A
HN18N-54H445W445 W38.9 V14.33 A

Frequently Asked Questions

What specs must match when replacing the Hanersun HN18N-54H425W?

The most critical specs to match are: cell count (must be exactly 108), Voc close to 38.1 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Hanersun HN18N-54H425W?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Hanersun HN18N-54H425W.