635 W TOPCon solar panel with 132 cells. Voc 49.6 V · Isc 16.26 A · TcVoc -0.24%/°C.
Select the panel you want to replace
199 panels found · 3501 panels excluded
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.6 V | 0.0% |
| Vmpp | 41.24 V | 41.24 V | 0.0% |
| Isc | 16.26 A | 16.26 A | 0.0% |
| Impp | 15.4 A | 15.4 A | 0.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.5 V | 0.2% |
| Vmpp | 41.24 V | 41.1 V | 0.3% |
| Isc | 16.26 A | 16.18 A | 0.5% |
| Impp | 15.4 A | 15.33 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.5 V | 0.2% |
| Vmpp | 41.24 V | 41.1 V | 0.3% |
| Isc | 16.26 A | 16.18 A | 0.5% |
| Impp | 15.4 A | 15.33 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.75 V | 0.3% |
| Vmpp | 41.24 V | 41.38 V | 0.3% |
| Isc | 16.26 A | 16.33 A | 0.4% |
| Impp | 15.4 A | 15.47 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.75 V | 0.3% |
| Vmpp | 41.24 V | 41.38 V | 0.3% |
| Isc | 16.26 A | 16.33 A | 0.4% |
| Impp | 15.4 A | 15.47 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.5 V | 0.2% |
| Vmpp | 41.24 V | 41.16 V | 0.2% |
| Isc | 16.26 A | 16.18 A | 0.5% |
| Impp | 15.4 A | 15.31 A | 0.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.62 V | 0.0% |
| Vmpp | 41.24 V | 41.64 V | 1.0% |
| Isc | 16.26 A | 16.25 A | 0.1% |
| Impp | 15.4 A | 15.25 A | 1.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.6 V | 0.0% |
| Vmpp | 41.24 V | 41.4 V | 0.4% |
| Isc | 16.26 A | 16.03 A | 1.4% |
| Impp | 15.4 A | 14.98 A | 2.7% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.52 V | 0.2% |
| Vmpp | 41.24 V | 41.22 V | 0.0% |
| Isc | 16.26 A | 16.55 A | 1.8% |
| Impp | 15.4 A | 15.65 A | 1.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.52 V | 0.2% |
| Vmpp | 41.24 V | 41.22 V | 0.0% |
| Isc | 16.26 A | 16.55 A | 1.8% |
| Impp | 15.4 A | 15.65 A | 1.6% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.68 V | 0.2% |
| Vmpp | 41.24 V | 41.16 V | 0.2% |
| Isc | 16.26 A | 16.26 A | 0.0% |
| Impp | 15.4 A | 15.43 A | 0.2% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.6 V | 49.65 V | 0.1% |
| Vmpp | 41.24 V | 41.35 V | 0.3% |
| Isc | 16.26 A | 16.22 A | 0.2% |
| Impp | 15.4 A | 15.37 A | 0.2% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.6 V
Vmpp
41.24 V
Isc
16.26 A
Impp
15.4 A
TcVoc
-0.24 %/°C
TcPmax
-0.28 %/°C
Pmax
635 W
Cells
132
Bifaciality
80%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
32.5 kg
The Heckert Solar ZEUS 2.1 132-635 is a 635 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 620 W | 49.1 V | 16.06 A | |
| 625 W | 49.3 V | 16.12 A | |
| 630 W | 49.5 V | 16.18 A | |
| 640 W | 49.75 V | 16.33 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.6 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Heckert Solar ZEUS 2.1 132-635.