420 W TOPCon solar panel with 108 cells. Voc 38.08 V · Isc 14.09 A · TcVoc -0.26%/°C.
Select the panel you want to replace
Panel not in the catalogue?
130 of the 4,444 panels in the catalogue can replace JA Solar JAM54D41-420/GB. Before you buy, check your pick in the string calculator with your inverter.
CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.
Small differences within tolerance — safe once verified in the calculator with your inverter.
Match 80–92 % · 22 models
Noticeable differences — the string voltage and current need a careful check.
Match 60–79 % · 63 models
Large differences — a real risk of a mismatched string; prefer a closer panel.
Match 32–59 % · 45 models
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
38.08 V
Vmpp
31.79 V
Isc
14.09 A
Impp
13.21 A
TcVoc
-0.26 %/°C
TcPmax
-0.3 %/°C
Pmax
420 W
Cells
108
Bifaciality
80%
Length
1722 mm
Width
1134 mm
Thickness
30 mm
Weight
21.5 kg
The JA Solar JAM54D41-420/GB is a 420 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JAM54D41-410/GB | 410 W | 37.85 V | 13.95 A |
| JAM54D41-415/GB | 415 W | 37.95 V | 14.02 A |
| JAM54D41-425/GB | 425 W | 38.23 V | 14.16 A |
| JAM54D41-430/GB | 430 W | 38.32 V | 14.23 A |
| JAM54D41-435/GB | 435 W | 38.48 V | 14.3 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 38.08 V (within ±5%), and temperature coefficient TcVoc close to -0.26%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JA Solar JAM54D41-420/GB.