455 W TOPCon solar panel with 96 cells. Voc 35.85 V · Isc 16.13 A · TcVoc -0.24%/°C.
Select the panel you want to replace
234 panels found · 3466 panels excluded
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.7 V | 0.4% |
| Vmpp | 30.08 V | 29.89 V | 0.6% |
| Isc | 16.13 A | 16.06 A | 0.4% |
| Impp | 15.13 A | 15.06 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 36 V | 0.4% |
| Vmpp | 30.08 V | 30.27 V | 0.6% |
| Isc | 16.13 A | 16.2 A | 0.4% |
| Impp | 15.13 A | 15.2 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.75 V | 0.3% |
| Vmpp | 30.08 V | 30.19 V | 0.4% |
| Isc | 16.13 A | 15.95 A | 1.1% |
| Impp | 15.13 A | 14.91 A | 1.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.9 V | 0.1% |
| Vmpp | 30.08 V | 30.2 V | 0.4% |
| Isc | 16.13 A | 16.17 A | 0.2% |
| Impp | 15.13 A | 15.24 A | 0.7% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.79 V | 0.2% |
| Vmpp | 30.08 V | 30.28 V | 0.7% |
| Isc | 16.13 A | 16.3 A | 1.1% |
| Impp | 15.13 A | 15.22 A | 0.6% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.98 V | 0.4% |
| Vmpp | 30.08 V | 30.01 V | 0.2% |
| Isc | 16.13 A | 15.95 A | 1.1% |
| Impp | 15.13 A | 15.17 A | 0.3% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.91 V | 0.2% |
| Vmpp | 30.08 V | 30.04 V | 0.1% |
| Isc | 16.13 A | 15.72 A | 2.5% |
| Impp | 15.13 A | 14.98 A | 1.0% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.8 V | 0.1% |
| Vmpp | 30.08 V | 29.93 V | 0.5% |
| Isc | 16.13 A | 15.9 A | 1.4% |
| Impp | 15.13 A | 15.04 A | 0.6% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.7 V | 0.4% |
| Vmpp | 30.08 V | 30 V | 0.3% |
| Isc | 16.13 A | 16.1 A | 0.2% |
| Impp | 15.13 A | 15.17 A | 0.3% |
| TcVoc | -0.24 %/°C | -0.23 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.78 V | 0.2% |
| Vmpp | 30.08 V | 29.81 V | 0.9% |
| Isc | 16.13 A | 15.9 A | 1.4% |
| Impp | 15.13 A | 15.1 A | 0.2% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.95 V | 0.3% |
| Vmpp | 30.08 V | 30.44 V | 1.2% |
| Isc | 16.13 A | 15.98 A | 0.9% |
| Impp | 15.13 A | 14.95 A | 1.2% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.28 %/°C | ±0.010 %/°C |
440 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 35.85 V | 35.84 V | 0.0% |
| Vmpp | 30.08 V | 29.68 V | 1.3% |
| Isc | 16.13 A | 15.52 A | 3.8% |
| Impp | 15.13 A | 14.83 A | 2.0% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
35.85 V
Vmpp
30.08 V
Isc
16.13 A
Impp
15.13 A
TcVoc
-0.24 %/°C
TcPmax
-0.29 %/°C
Pmax
455 W
Cells
96
Bifaciality
80%
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
23.7 kg
The Jetion Solar JT455SNt(B) is a 455 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 440 W | 35.3 V | 15.92 A | |
| 445 W | 35.5 V | 15.99 A | |
| 450 W | 35.7 V | 16.06 A | |
| 460 W | 36 V | 16.2 A |
The most critical specs to match are: cell count (must be exactly 96), Voc close to 35.85 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Jetion Solar JT455SNt(B).