260 W Poly solar panel with 60 cells. Voc 38.1 V · Isc 8.98 A · TcVoc -0.31%/°C.
Select the panel you want to replace
Panel not in the catalogue?
25 of the 4,444 panels in the catalogue can replace JinkoSolar JKM260P-60. Before you buy, check your pick in the string calculator with your inverter.
CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.
Small differences within tolerance — safe once verified in the calculator with your inverter.
Match 90 % · 1 model
Noticeable differences — the string voltage and current need a careful check.
Match 60–78 % · 10 models
Large differences — a real risk of a mismatched string; prefer a closer panel.
Match 24–57 % · 14 models
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
38.1 V
Vmpp
31.1 V
Isc
8.98 A
Impp
8.37 A
TcVoc
-0.31 %/°C
TcPmax
-0.41 %/°C
Pmax
260 W
Cells
60
Length
1650 mm
Width
992 mm
Thickness
40 mm
Weight
18.5 kg
The JinkoSolar JKM260P-60 is a 260 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JKM245P-60 | 245 W | 37.5 V | 8.76 A |
| JKM250P-60 | 250 W | 37.7 V | 8.85 A |
| JKM255P-60 | 255 W | 38 V | 8.92 A |
| JKM265P-60 | 265 W | 38.6 V | 9.03 A |
The most critical specs to match are: cell count (must be exactly 60), Voc close to 38.1 V (within ±5%), and temperature coefficient TcVoc close to -0.31%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM260P-60.