565 W TOPCon solar panel with 144 cells. Voc 51.9 V · Isc 13.77 A · TcVoc -0.25%/°C.
Select the panel you want to replace
155 panels found · 4184 panels excluded
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.77 V | 0.3% |
| Vmpp | 43.43 V | 43.4 V | 0.1% |
| Isc | 13.77 A | 14.01 A | 1.7% |
| Impp | 13.01 A | 13.15 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.9 V | 0.0% |
| Vmpp | 43.43 V | 43.2 V | 0.5% |
| Isc | 13.77 A | 14.01 A | 1.7% |
| Impp | 13.01 A | 13.32 A | 2.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.97 V | 0.1% |
| Vmpp | 43.43 V | 43.6 V | 0.4% |
| Isc | 13.77 A | 14.06 A | 2.1% |
| Impp | 13.01 A | 13.21 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 52.1 V | 0.4% |
| Vmpp | 43.43 V | 43.58 V | 0.3% |
| Isc | 13.77 A | 13.83 A | 0.4% |
| Impp | 13.01 A | 13.08 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 52 V | 0.2% |
| Vmpp | 43.43 V | 43.37 V | 0.1% |
| Isc | 13.77 A | 13.94 A | 1.2% |
| Impp | 13.01 A | 13.26 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.95 V | 0.1% |
| Vmpp | 43.43 V | 44.02 V | 1.4% |
| Isc | 13.77 A | 13.84 A | 0.5% |
| Impp | 13.01 A | 13.17 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.9 V | 0.0% |
| Vmpp | 43.43 V | 43.56 V | 0.3% |
| Isc | 13.77 A | 13.75 A | 0.1% |
| Impp | 13.01 A | 12.97 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 52.1 V | 0.4% |
| Vmpp | 43.43 V | 43.4 V | 0.1% |
| Isc | 13.77 A | 14.07 A | 2.2% |
| Impp | 13.01 A | 13.37 A | 2.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.75 V | 0.3% |
| Vmpp | 43.43 V | 43.56 V | 0.3% |
| Isc | 13.77 A | 13.95 A | 1.3% |
| Impp | 13.01 A | 13.2 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.9 V | 0.0% |
| Vmpp | 43.43 V | 43.75 V | 0.7% |
| Isc | 13.77 A | 14.01 A | 1.7% |
| Impp | 13.01 A | 13.26 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.57 V | 0.6% |
| Vmpp | 43.43 V | 43.2 V | 0.5% |
| Isc | 13.77 A | 13.95 A | 1.3% |
| Impp | 13.01 A | 13.1 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.9 V | 51.73 V | 0.3% |
| Vmpp | 43.43 V | 42.86 V | 1.3% |
| Isc | 13.77 A | 13.95 A | 1.3% |
| Impp | 13.01 A | 13.3 A | 2.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
51.9 V
Vmpp
43.43 V
Isc
13.77 A
Impp
13.01 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
565 W
Cells
144
Bifaciality
80%
Length
2278 mm
Width
1134 mm
Thickness
30 mm
Weight
31 kg
The JinkoSolar JKM565N-72HL4-BDV is a 565 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JKM570N-72HL4-BDV | 570 W | 52.1 V | 13.83 A |
| JKM575N-72HL4-BDV | 575 W | 52.3 V | 13.89 A |
| JKM580N-72HL4-BDV | 580 W | 52.5 V | 13.95 A |
| JKM585N-72HL4-BDV | 585 W | 52.7 V | 14.01 A |
| JKM590N-72HL4-BDV | 590 W | 52.9 V | 14.07 A |
| JKM595N-72HL4-BDV | 595 W | 53.1 V | 14.13 A |
| JKM600N-72HL4-BDV | 600 W | 53.3 V | 14.19 A |
| JKM605N-72HL4-BDV | 605 W | 53.5 V | 14.25 A |
| JKM610N-72HL4-BDV | 610 W | 53.7 V | 14.31 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 51.9 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM565N-72HL4-BDV.