580 W TOPCon solar panel with 144 cells. Voc 52.5 V · Isc 13.95 A · TcVoc -0.25%/°C.
Select the panel you want to replace
217 panels found · 4122 panels excluded
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.5 V | 0.0% |
| Vmpp | 43.88 V | 43.85 V | 0.1% |
| Isc | 13.95 A | 13.99 A | 0.3% |
| Impp | 13.22 A | 13.24 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.52 V | 0.0% |
| Vmpp | 43.88 V | 44.02 V | 0.3% |
| Isc | 13.95 A | 13.95 A | 0.0% |
| Impp | 13.22 A | 13.18 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.5 V | 0.0% |
| Vmpp | 43.88 V | 43.8 V | 0.2% |
| Isc | 13.95 A | 14.19 A | 1.7% |
| Impp | 13.22 A | 13.48 A | 2.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.45 V | 0.1% |
| Vmpp | 43.88 V | 44.08 V | 0.5% |
| Isc | 13.95 A | 14.08 A | 0.9% |
| Impp | 13.22 A | 13.27 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.32 V | 0.3% |
| Vmpp | 43.88 V | 43.85 V | 0.1% |
| Isc | 13.95 A | 13.89 A | 0.4% |
| Impp | 13.22 A | 13.11 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.5 V | 0.0% |
| Vmpp | 43.88 V | 44.1 V | 0.5% |
| Isc | 13.95 A | 13.9 A | 0.4% |
| Impp | 13.22 A | 13.27 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.3 V | 0.4% |
| Vmpp | 43.88 V | 43.95 V | 0.2% |
| Isc | 13.95 A | 13.98 A | 0.2% |
| Impp | 13.22 A | 13.2 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.7 V | 0.4% |
| Vmpp | 43.88 V | 44.02 V | 0.3% |
| Isc | 13.95 A | 14.01 A | 0.4% |
| Impp | 13.22 A | 13.29 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.3 V | 0.4% |
| Vmpp | 43.88 V | 43.73 V | 0.3% |
| Isc | 13.95 A | 13.89 A | 0.4% |
| Impp | 13.22 A | 13.15 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.37 V | 0.2% |
| Vmpp | 43.88 V | 44 V | 0.3% |
| Isc | 13.95 A | 14.18 A | 1.6% |
| Impp | 13.22 A | 13.32 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.7 V | 0.4% |
| Vmpp | 43.88 V | 44.04 V | 0.4% |
| Isc | 13.95 A | 14.05 A | 0.7% |
| Impp | 13.22 A | 13.3 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
590 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.5 V | 52.6 V | 0.2% |
| Vmpp | 43.88 V | 44.2 V | 0.7% |
| Isc | 13.95 A | 14.18 A | 1.6% |
| Impp | 13.22 A | 13.35 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
52.5 V
Vmpp
43.88 V
Isc
13.95 A
Impp
13.22 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
580 W
Cells
144
Bifaciality
80%
Length
2278 mm
Width
1134 mm
Thickness
30 mm
Weight
31 kg
The JinkoSolar JKM580N-72HL4-BDV is a 580 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JKM565N-72HL4-BDV | 565 W | 51.9 V | 13.77 A |
| JKM570N-72HL4-BDV | 570 W | 52.1 V | 13.83 A |
| JKM575N-72HL4-BDV | 575 W | 52.3 V | 13.89 A |
| JKM585N-72HL4-BDV | 585 W | 52.7 V | 14.01 A |
| JKM590N-72HL4-BDV | 590 W | 52.9 V | 14.07 A |
| JKM595N-72HL4-BDV | 595 W | 53.1 V | 14.13 A |
| JKM600N-72HL4-BDV | 600 W | 53.3 V | 14.19 A |
| JKM605N-72HL4-BDV | 605 W | 53.5 V | 14.25 A |
| JKM610N-72HL4-BDV | 610 W | 53.7 V | 14.31 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 52.5 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM580N-72HL4-BDV.