625 W TOPCon solar panel with 156 cells. Voc 55.7 V · Isc 14.32 A · TcVoc -0.25%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

9 panels found · 4330 panels excluded

JinkoSolar JKM625N-78HL4-V

625 W

TOPCon
100Exact match
ParameterOriginalReplacementDeviation
Voc55.7 V55.7 V0.0%
Vmpp45.92 V45.92 V0.0%
Isc14.32 A14.32 A0.0%
Impp13.61 A13.61 A0.0%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM620N-78HL4

620 W

TOPCon
94Good match
ParameterOriginalReplacementDeviation
Voc55.7 V55.55 V0.3%
Vmpp45.92 V45.79 V0.3%
Isc14.32 A14.25 A0.5%
Impp13.61 A13.54 A0.5%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM620N-78HL4-V

620 W

TOPCon
94Good match
ParameterOriginalReplacementDeviation
Voc55.7 V55.55 V0.3%
Vmpp45.92 V45.79 V0.3%
Isc14.32 A14.25 A0.5%
Impp13.61 A13.54 A0.5%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM630N-78HL4

630 W

TOPCon
94Good match
ParameterOriginalReplacementDeviation
Voc55.7 V55.85 V0.3%
Vmpp45.92 V46.02 V0.2%
Isc14.32 A14.39 A0.5%
Impp13.61 A13.69 A0.6%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM630N-78HL4-V

630 W

TOPCon
94Good match
ParameterOriginalReplacementDeviation
Voc55.7 V55.85 V0.3%
Vmpp45.92 V46.02 V0.2%
Isc14.32 A14.39 A0.5%
Impp13.61 A13.69 A0.6%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM635N-78HL4

635 W

TOPCon
89Good match
ParameterOriginalReplacementDeviation
Voc55.7 V56 V0.5%
Vmpp45.92 V46.12 V0.4%
Isc14.32 A14.46 A1.0%
Impp13.61 A13.75 A1.0%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM635N-78HL4-V

635 W

TOPCon
89Good match
ParameterOriginalReplacementDeviation
Voc55.7 V56 V0.5%
Vmpp45.92 V46.12 V0.4%
Isc14.32 A14.46 A1.0%
Impp13.61 A13.75 A1.0%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM615N-78HL4

615 W

TOPCon
88Good match
ParameterOriginalReplacementDeviation
Voc55.7 V55.4 V0.5%
Vmpp45.92 V45.69 V0.5%
Isc14.32 A14.18 A1.0%
Impp13.61 A13.46 A1.1%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM615N-78HL4-V

615 W

TOPCon
88Good match
ParameterOriginalReplacementDeviation
Voc55.7 V55.4 V0.5%
Vmpp45.92 V45.69 V0.5%
Isc14.32 A14.18 A1.0%
Impp13.61 A13.46 A1.1%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

55.7 V

Vmpp

45.92 V

Isc

14.32 A

Impp

13.61 A

TcVoc

-0.25 %/°C

TcPmax

-0.29 %/°C

Pmax

625 W

Cells

156

Length

2465 mm

Width

1134 mm

Thickness

35 mm

Weight

30.6 kg

The JinkoSolar JKM625N-78HL4 is a 625 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
JKM615N-78HL4615 W55.4 V14.18 A
JKM615N-78HL4-V615 W55.4 V14.18 A
JKM620N-78HL4620 W55.55 V14.25 A
JKM620N-78HL4-V620 W55.55 V14.25 A
JKM625N-78HL4-V625 W55.7 V14.32 A
JKM630N-78HL4630 W55.85 V14.39 A
JKM630N-78HL4-V630 W55.85 V14.39 A
JKM635N-78HL4635 W56 V14.46 A
JKM635N-78HL4-V635 W56 V14.46 A

Frequently Asked Questions

What specs must match when replacing the JinkoSolar JKM625N-78HL4?

The most critical specs to match are: cell count (must be exactly 156), Voc close to 55.7 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the JinkoSolar JKM625N-78HL4?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM625N-78HL4.