635 W TOPCon solar panel with 156 cells. Voc 56 V · Isc 14.46 A · TcVoc -0.25%/°C.
Select the panel you want to replace
9 panels found · 4330 panels excluded
635 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 56 V | 0.0% |
| Vmpp | 46.12 V | 46.12 V | 0.0% |
| Isc | 14.46 A | 14.46 A | 0.0% |
| Impp | 13.75 A | 13.75 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 55.85 V | 0.3% |
| Vmpp | 46.12 V | 46.02 V | 0.2% |
| Isc | 14.46 A | 14.39 A | 0.5% |
| Impp | 13.75 A | 13.69 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 55.85 V | 0.3% |
| Vmpp | 46.12 V | 46.02 V | 0.2% |
| Isc | 14.46 A | 14.39 A | 0.5% |
| Impp | 13.75 A | 13.69 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 55.7 V | 0.5% |
| Vmpp | 46.12 V | 45.92 V | 0.4% |
| Isc | 14.46 A | 14.32 A | 1.0% |
| Impp | 13.75 A | 13.61 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 55.7 V | 0.5% |
| Vmpp | 46.12 V | 45.92 V | 0.4% |
| Isc | 14.46 A | 14.32 A | 1.0% |
| Impp | 13.75 A | 13.61 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 55.55 V | 0.8% |
| Vmpp | 46.12 V | 45.79 V | 0.7% |
| Isc | 14.46 A | 14.25 A | 1.5% |
| Impp | 13.75 A | 13.54 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 55.55 V | 0.8% |
| Vmpp | 46.12 V | 45.79 V | 0.7% |
| Isc | 14.46 A | 14.25 A | 1.5% |
| Impp | 13.75 A | 13.54 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 55.4 V | 1.1% |
| Vmpp | 46.12 V | 45.69 V | 0.9% |
| Isc | 14.46 A | 14.18 A | 1.9% |
| Impp | 13.75 A | 13.46 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 56 V | 55.4 V | 1.1% |
| Vmpp | 46.12 V | 45.69 V | 0.9% |
| Isc | 14.46 A | 14.18 A | 1.9% |
| Impp | 13.75 A | 13.46 A | 2.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
56 V
Vmpp
46.12 V
Isc
14.46 A
Impp
13.75 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
635 W
Cells
156
Length
2465 mm
Width
1134 mm
Thickness
35 mm
Weight
30.6 kg
The JinkoSolar JKM635N-78HL4-V is a 635 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JKM615N-78HL4 | 615 W | 55.4 V | 14.18 A |
| JKM615N-78HL4-V | 615 W | 55.4 V | 14.18 A |
| JKM620N-78HL4 | 620 W | 55.55 V | 14.25 A |
| JKM620N-78HL4-V | 620 W | 55.55 V | 14.25 A |
| JKM625N-78HL4 | 625 W | 55.7 V | 14.32 A |
| JKM625N-78HL4-V | 625 W | 55.7 V | 14.32 A |
| JKM630N-78HL4 | 630 W | 55.85 V | 14.39 A |
| JKM630N-78HL4-V | 630 W | 55.85 V | 14.39 A |
| JKM635N-78HL4 | 635 W | 56 V | 14.46 A |
The most critical specs to match are: cell count (must be exactly 156), Voc close to 56 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM635N-78HL4-V.