Find replacement for JinkoSolar JKM705N-66HL5-BDV

705 W TOPCon solar panel with 132 cells. Voc 48.56 V · Isc 18.46 A · TcVoc -0.25%/°C.

Select the panel you want to replace

Show only panels with matching cell technology

Compatible Replacements

154 panels found · 4185 panels excluded

Seraphim SRP-700-BTC-BG

700 W

TOPCon
97Exact match
ParameterOriginalReplacementDeviation
Voc48.56 V48.5 V0.1%
Vmpp40.53 V40.53 V0.0%
Isc18.46 A18.32 A0.8%
Impp17.4 A17.28 A0.7%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JA Solar JAM66D46-710/LB

710 W

TOPCon
96Exact match
ParameterOriginalReplacementDeviation
Voc48.56 V48.6 V0.1%
Vmpp40.53 V40.8 V0.7%
Isc18.46 A18.51 A0.3%
Impp17.4 A17.4 A0.0%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Ulica Solar UL-700M-132DGN

700 W

TOPCon
96Exact match
ParameterOriginalReplacementDeviation
Voc48.56 V48.62 V0.1%
Vmpp40.53 V40.54 V0.0%
Isc18.46 A18.32 A0.8%
Impp17.4 A17.27 A0.7%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JA Solar JAM66D46-705/LB

705 W

TOPCon
95Exact match
ParameterOriginalReplacementDeviation
Voc48.56 V48.4 V0.3%
Vmpp40.53 V40.61 V0.2%
Isc18.46 A18.47 A0.1%
Impp17.4 A17.36 A0.2%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Canadian Solar CS7N-715TB-AG

715 W

TOPCon
95Exact match
ParameterOriginalReplacementDeviation
Voc48.56 V48.5 V0.1%
Vmpp40.53 V40.6 V0.2%
Isc18.46 A18.64 A1.0%
Impp17.4 A17.63 A1.3%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM700N-66HL5-BDV

700 W

TOPCon
94Good match
ParameterOriginalReplacementDeviation
Voc48.56 V48.4 V0.3%
Vmpp40.53 V40.42 V0.3%
Isc18.46 A18.4 A0.3%
Impp17.4 A17.32 A0.5%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Seraphim SRP-705-BTC-BG

705 W

TOPCon
93Good match
ParameterOriginalReplacementDeviation
Voc48.56 V48.7 V0.3%
Vmpp40.53 V40.73 V0.5%
Isc18.46 A18.36 A0.5%
Impp17.4 A17.31 A0.5%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Luxor Solar LX-695M/210-132+ GG BW ECOLINE

695 W

TOPCon
93Good match
ParameterOriginalReplacementDeviation
Voc48.56 V48.64 V0.2%
Vmpp40.53 V40.18 V0.9%
Isc18.46 A18.4 A0.3%
Impp17.4 A17.3 A0.6%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Astronergy CHSM66NDGF-BH710

710 W

TOPCon
93Good match
ParameterOriginalReplacementDeviation
Voc48.56 V48.77 V0.4%
Vmpp40.53 V40.48 V0.1%
Isc18.46 A18.48 A0.1%
Impp17.4 A17.54 A0.8%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
JinkoSolar JKM710N-66HL5-BDV

710 W

TOPCon
93Good match
ParameterOriginalReplacementDeviation
Voc48.56 V48.73 V0.4%
Vmpp40.53 V40.65 V0.3%
Isc18.46 A18.53 A0.4%
Impp17.4 A17.47 A0.4%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Trina Solar TSM-NEG21C.20-700

700 W

TOPCon
92Good match
ParameterOriginalReplacementDeviation
Voc48.56 V48.6 V0.1%
Vmpp40.53 V40.5 V0.1%
Isc18.46 A18.32 A0.8%
Impp17.4 A17.29 A0.6%
TcVoc-0.25 %/°C-0.24 %/°C±0.010 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C
Ulica Solar UL-705M-132DGN

705 W

TOPCon
92Good match
ParameterOriginalReplacementDeviation
Voc48.56 V48.77 V0.4%
Vmpp40.53 V40.69 V0.4%
Isc18.46 A18.38 A0.4%
Impp17.4 A17.33 A0.4%
TcVoc-0.25 %/°C-0.25 %/°C±0.000 %/°C
TcPmax-0.29 %/°C-0.29 %/°C±0.000 %/°C

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

48.56 V

Vmpp

40.53 V

Isc

18.46 A

Impp

17.4 A

TcVoc

-0.25 %/°C

TcPmax

-0.29 %/°C

Pmax

705 W

Cells

132

Bifaciality

80%

Length

2384 mm

Width

1303 mm

Thickness

33 mm

Weight

37.5 kg

The JinkoSolar JKM705N-66HL5-BDV is a 705 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
JKM700N-66HL5-BDV700 W48.4 V18.4 A
JKM710N-66HL5-BDV710 W48.73 V18.53 A
JKM715N-66HL5-BDV715 W48.88 V18.6 A
JKM720N-66HL5-BDV720 W49.04 V18.67 A
JKM725N-66HL5-BDV725 W49.2 V18.74 A

Frequently Asked Questions

What specs must match when replacing the JinkoSolar JKM705N-66HL5-BDV?

The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.56 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the JinkoSolar JKM705N-66HL5-BDV?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM705N-66HL5-BDV.