715 W TOPCon solar panel with 132 cells. Voc 48.88 V · Isc 18.6 A · TcVoc -0.25%/°C.
Select the panel you want to replace
179 panels found · 4160 panels excluded
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.82 V | 0.1% |
| Vmpp | 40.77 V | 40.76 V | 0.0% |
| Isc | 18.6 A | 18.52 A | 0.4% |
| Impp | 17.54 A | 17.45 A | 0.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.8 V | 0.2% |
| Vmpp | 40.77 V | 41 V | 0.6% |
| Isc | 18.6 A | 18.55 A | 0.3% |
| Impp | 17.54 A | 17.44 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.9 V | 0.0% |
| Vmpp | 40.77 V | 41 V | 0.6% |
| Isc | 18.6 A | 18.74 A | 0.8% |
| Impp | 17.54 A | 17.71 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.97 V | 0.2% |
| Vmpp | 40.77 V | 40.65 V | 0.3% |
| Isc | 18.6 A | 18.53 A | 0.4% |
| Impp | 17.54 A | 17.59 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.9 V | 0.0% |
| Vmpp | 40.77 V | 40.93 V | 0.4% |
| Isc | 18.6 A | 18.4 A | 1.1% |
| Impp | 17.54 A | 17.35 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.82 V | 0.1% |
| Vmpp | 40.77 V | 40.93 V | 0.4% |
| Isc | 18.6 A | 18.4 A | 1.1% |
| Impp | 17.54 A | 17.35 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 49.02 V | 0.3% |
| Vmpp | 40.77 V | 40.93 V | 0.4% |
| Isc | 18.6 A | 18.56 A | 0.2% |
| Impp | 17.54 A | 17.5 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
730 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.85 V | 0.1% |
| Vmpp | 40.77 V | 40.85 V | 0.2% |
| Isc | 18.6 A | 18.91 A | 1.7% |
| Impp | 17.54 A | 17.87 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.73 V | 0.3% |
| Vmpp | 40.77 V | 40.65 V | 0.3% |
| Isc | 18.6 A | 18.53 A | 0.4% |
| Impp | 17.54 A | 17.47 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 49.04 V | 0.3% |
| Vmpp | 40.77 V | 40.89 V | 0.3% |
| Isc | 18.6 A | 18.67 A | 0.4% |
| Impp | 17.54 A | 17.61 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.77 V | 0.2% |
| Vmpp | 40.77 V | 40.69 V | 0.2% |
| Isc | 18.6 A | 18.38 A | 1.2% |
| Impp | 17.54 A | 17.33 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
700 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.88 V | 48.89 V | 0.0% |
| Vmpp | 40.77 V | 40.38 V | 1.0% |
| Isc | 18.6 A | 18.45 A | 0.8% |
| Impp | 17.54 A | 17.34 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.88 V
Vmpp
40.77 V
Isc
18.6 A
Impp
17.54 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
715 W
Cells
132
Bifaciality
80%
Length
2384 mm
Width
1303 mm
Thickness
33 mm
Weight
37.5 kg
The JinkoSolar JKM715N-66HL5-BDV is a 715 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| JKM700N-66HL5-BDV | 700 W | 48.4 V | 18.4 A |
| JKM705N-66HL5-BDV | 705 W | 48.56 V | 18.46 A |
| JKM710N-66HL5-BDV | 710 W | 48.73 V | 18.53 A |
| JKM720N-66HL5-BDV | 720 W | 49.04 V | 18.67 A |
| JKM725N-66HL5-BDV | 725 W | 49.2 V | 18.74 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.88 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original JinkoSolar JKM715N-66HL5-BDV.