Find replacement for Leapton Energy LP210*210-M-66-NB-725W

725 W TOPCon solar panel with 132 cells. Voc 49.2 V · Isc 18.7 A · TcVoc -0.25%/°C.

Select the panel you want to replace

Panel not in the catalogue?

176 of the 4,444 panels in the catalogue can replace Leapton Energy LP210*210-M-66-NB-725W. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Exact match

Near-identical electrics — a drop-in swap for the same string.

Match 95 % · 2 models

  • DMEGC DM720G12T-B66HSW — Open the panel page
    720 WTOPCon
    95 %
  • JinkoSolar JKM725N-66HL5-BDV — Open the panel page
    725 WTOPCon
    95 %

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 80–94 % · 61 models

  • Canadian Solar CS7N-730TB-AG — Open the panel page
    730 WTOPCon
    94 %
  • Perlight Solar PLM-720DH2N-132 — Open the panel page
    720 WTOPCon
    94 %
  • Leapton Energy LP210*210-M-66-NB-720W — Open the panel page
    720 WTOPConsame series
    92 %
  • Leapton Energy LP210*210-M-66-NB-730W — Open the panel page
    730 WTOPConsame series
    92 %
  • DMEGC DM725G12T-B66HSW — Open the panel page
    725 WTOPCon
    92 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 60–79 % · 68 models

  • DAH Solar DHN-66Y18/DG-725W — Open the panel page
    725 WTOPCon
    79 %
  • DAH Solar DHN-66Y18/DG(BW)-725W — Open the panel page
    725 WTOPCon
    79 %
  • DMEGC DM735G12T-B66HSW — Open the panel page
    735 WTOPCon
    79 %
  • SUNPLUS SR5-66HNH-715M — Open the panel page
    715 WTOPCon
    79 %
  • Tongwei TWMNF-66HD730 — Open the panel page
    730 WTOPCon
    79 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 27–59 % · 45 models

  • Suntech STP710S-D66-Nsh+ — Open the panel page
    710 WTOPCon
    59 %
  • Trina Solar TSM-NEG21C.20-740 — Open the panel page
    740 WTOPCon
    58 %
  • GCL-NT12/66GDF 710 — Open the panel page
    710 WTOPCon
    57 %
  • Sun Earth DXM12-66HBG 730W — Open the panel page
    730 WTOPCon
    48 %
  • Bluesun Solar BSM725G12-66HNH — Open the panel page
    725 WHJT
    43 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

49.2 V

Vmpp

41.2 V

Isc

18.7 A

Impp

17.6 A

TcVoc

-0.25 %/°C

TcPmax

-0.3 %/°C

Pmax

725 W

Cells

132

Bifaciality

80%

Length

2384 mm

Width

1303 mm

Thickness

33 mm

Weight

37.5 kg

The Leapton Energy LP210*210-M-66-NB-725W is a 725 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
LP210*210-M-66-NB-690W690 W47.8 V18.3 A
LP210*210-M-66-NB-695W695 W48 V18.4 A
LP210*210-M-66-NB-700W700 W48.2 V18.48 A
LP210*210-M-66-NB-705W705 W48.4 V18.52 A
LP210*210-M-66-NB-710W710 W48.6 V18.57 A
LP210*210-M-66-NB-715W715 W48.8 V18.61 A
LP210*210-M-66-NB-720W720 W49 V18.65 A
LP210*210-M-66-NB-730W730 W49.4 V18.74 A

Frequently Asked Questions

What specs must match when replacing the Leapton Energy LP210*210-M-66-NB-725W?

The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.2 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Leapton Energy LP210*210-M-66-NB-725W?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Leapton Energy LP210*210-M-66-NB-725W.