570 W HPBC solar panel with 144 cells. Voc 52.99 V · Isc 13.26 A · TcVoc -0.2%/°C.
Select the panel you want to replace
27 panels found · 3673 panels excluded
575 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 53.19 V | 0.4% |
| Vmpp | 45.57 V | 45.74 V | 0.4% |
| Isc | 13.26 A | 13.31 A | 0.4% |
| Impp | 12.6 A | 12.64 A | 0.3% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
550 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 52.96 V | 0.1% |
| Vmpp | 45.57 V | 45.86 V | 0.6% |
| Isc | 13.26 A | 12.8 A | 3.5% |
| Impp | 12.6 A | 12.06 A | 4.3% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
580 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 53.39 V | 0.8% |
| Vmpp | 45.57 V | 45.92 V | 0.8% |
| Isc | 13.26 A | 13.39 A | 1.0% |
| Impp | 12.6 A | 12.69 A | 0.7% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
555 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 53.16 V | 0.3% |
| Vmpp | 45.57 V | 46.03 V | 1.0% |
| Isc | 13.26 A | 12.85 A | 3.1% |
| Impp | 12.6 A | 12.11 A | 3.9% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
560 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 53.36 V | 0.7% |
| Vmpp | 45.57 V | 46.21 V | 1.4% |
| Isc | 13.26 A | 12.9 A | 2.7% |
| Impp | 12.6 A | 12.15 A | 3.6% |
| TcVoc | -0.2 %/°C | -0.2 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
590 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 52.51 V | 0.9% |
| Vmpp | 45.57 V | 44.36 V | 2.7% |
| Isc | 13.26 A | 14.33 A | 8.1% |
| Impp | 12.6 A | 13.31 A | 5.6% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
590 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 52.51 V | 0.9% |
| Vmpp | 45.57 V | 44.36 V | 2.7% |
| Isc | 13.26 A | 14.33 A | 8.1% |
| Impp | 12.6 A | 13.31 A | 5.6% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
590 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 52.51 V | 0.9% |
| Vmpp | 45.57 V | 44.36 V | 2.7% |
| Isc | 13.26 A | 14.33 A | 8.1% |
| Impp | 12.6 A | 13.31 A | 5.6% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
585 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 52.36 V | 1.2% |
| Vmpp | 45.57 V | 44.21 V | 3.0% |
| Isc | 13.26 A | 14.27 A | 7.6% |
| Impp | 12.6 A | 13.24 A | 5.1% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
585 W
IBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 52.36 V | 1.2% |
| Vmpp | 45.57 V | 44.21 V | 3.0% |
| Isc | 13.26 A | 14.27 A | 7.6% |
| Impp | 12.6 A | 13.24 A | 5.1% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
585 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 52.36 V | 1.2% |
| Vmpp | 45.57 V | 44.21 V | 3.0% |
| Isc | 13.26 A | 14.27 A | 7.6% |
| Impp | 12.6 A | 13.24 A | 5.1% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
580 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 52.99 V | 52.21 V | 1.5% |
| Vmpp | 45.57 V | 44.06 V | 3.3% |
| Isc | 13.26 A | 14.2 A | 7.1% |
| Impp | 12.6 A | 13.17 A | 4.5% |
| TcVoc | -0.2 %/°C | -0.23 %/°C | ±0.030 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
52.99 V
Vmpp
45.57 V
Isc
13.26 A
Impp
12.6 A
TcVoc
-0.2 %/°C
TcPmax
-0.26 %/°C
Pmax
570 W
Cells
144
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
33.5 kg
The LONGi LGi7-72CHVD-570M is a 570 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 420 W | 52.79 V | 9.75 A | |
| 425 W | 52.99 V | 9.8 A | |
| 430 W | 53.19 V | 9.85 A | |
| 480 W | 52.68 V | 11.23 A | |
| 485 W | 52.88 V | 11.28 A | |
| 490 W | 53.08 V | 11.33 A | |
| 490 W | 53.11 V | 11.38 A | |
| 495 W | 53.31 V | 11.43 A | |
| 500 W | 53.51 V | 11.48 A | |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 52.99 V (within ±5%), and temperature coefficient TcVoc close to -0.2%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original LONGi LGi7-72CHVD-570M.
| LGi7-72CHVD-550M |
| 550 W |
| 52.96 V |
| 12.8 A |
| LGi7-72CHVD-555M | 555 W | 53.16 V | 12.85 A |
| LGi7-72CHVD-560M | 560 W | 53.36 V | 12.9 A |
| LGi7-72CHVD-575M | 575 W | 53.19 V | 13.31 A |
| LGi7-72CHVD-580M | 580 W | 53.39 V | 13.39 A |