405 W PERC solar panel with 108 cells. Voc 37.26 V · Isc 13.67 A · TcVoc -0.285%/°C.

Select the panel you want to replace

Panel not in the catalogue?

101 of the 4,444 panels in the catalogue can replace Luxor Solar LX-405M/182-108+ BB HC. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Exact match

Near-identical electrics — a drop-in swap for the same string.

Match 96 % · 2 models

  • Luxor Solar LX-405M/182-108+ BW HC — Open the panel page
    405 WPERC
    96 %
  • Luxor Solar LX-405M/182-108+ SW HC — Open the panel page
    405 WPERC
    96 %

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 80–90 % · 24 models

  • Luxor Solar LX-400M/182-108+ BW HC — Open the panel page
    400 WPERC
    90 %
  • Luxor Solar LX-400M/182-108+ SW HC — Open the panel page
    400 WPERC
    90 %
  • GCL-M10/54H 415 — Open the panel page
    415 WPERC
    89 %
  • S-Energy SL65-54MAJ-405Z — Open the panel page
    405 WPERC
    89 %
  • S-Energy SL65-54MBJ-405Z — Open the panel page
    405 WPERC
    89 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 61–79 % · 45 models

  • Yingli Solar YL410D-37e 1/2 — Open the panel page
    410 WPERC
    79 %
  • Sunway SW415M-108 — Open the panel page
    415 WPERC
    76 %
  • Yingli Solar YL405D-37e 1/2 — Open the panel page
    405 WPERC
    76 %
  • Yingli Solar YL415D-37e 1/2 — Open the panel page
    415 WPERC
    76 %
  • Luxor Solar LX-395M/182-108+ BB HC — Open the panel page
    395 WPERCsame series
    75 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 30–59 % · 30 models

  • LONGi LR5-54HIH-400M — Open the panel page
    400 WPERC
    59 %
  • GCL-M10/54H 390 — Open the panel page
    390 WPERC
    56 %
  • LONGi LR5-54HIH-420M — Open the panel page
    420 WPERC
    56 %
  • LONGi LR5-54HPH-420M — Open the panel page
    420 WPERC
    56 %
  • München Solar MSMD390M10-54 — Open the panel page
    390 WPERC
    54 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

37.26 V

Vmpp

31.3 V

Isc

13.67 A

Impp

12.95 A

TcVoc

-0.285 %/°C

TcPmax

-0.36 %/°C

Pmax

405 W

Cells

108

Length

1722 mm

Width

1134 mm

Thickness

30 mm

Weight

21.5 kg

The Luxor Solar LX-405M/182-108+ BB HC is a 405 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
LX-395M/182-108+ BB HC395 W36.77 V13.52 A
LX-400M/182-108+ BB HC400 W37.01 V13.6 A
LX-410M/182-108+ BB HC410 W37.51 V13.75 A
LX-415M/182-108+ BB HC415 W37.76 V13.82 A

Frequently Asked Questions

What specs must match when replacing the Luxor Solar LX-405M/182-108+ BB HC?

The most critical specs to match are: cell count (must be exactly 108), Voc close to 37.26 V (within ±5%), and temperature coefficient TcVoc close to -0.285%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Luxor Solar LX-405M/182-108+ BB HC?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Luxor Solar LX-405M/182-108+ BB HC.