430 W HJT solar panel with 108 cells. Voc 41.09 V · Isc 13.67 A · TcVoc -0.26%/°C.
Select the panel you want to replace
37 panels found · 3673 panels excluded
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 41.25 V | 0.4% |
| Vmpp | 33.49 V | 33.62 V | 0.4% |
| Isc | 13.67 A | 13.78 A | 0.8% |
| Impp | 12.85 A | 12.95 A | 0.8% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 41.41 V | 0.8% |
| Vmpp | 33.49 V | 33.75 V | 0.8% |
| Isc | 13.67 A | 13.88 A | 1.5% |
| Impp | 12.85 A | 13.05 A | 1.6% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 41.58 V | 1.2% |
| Vmpp | 33.49 V | 33.89 V | 1.2% |
| Isc | 13.67 A | 13.98 A | 2.3% |
| Impp | 12.85 A | 13.14 A | 2.3% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 41.09 V | 0.0% |
| Vmpp | 33.49 V | 34.26 V | 2.3% |
| Isc | 13.67 A | 13.45 A | 1.6% |
| Impp | 12.85 A | 12.99 A | 1.1% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 40.83 V | 0.6% |
| Vmpp | 33.49 V | 34.01 V | 1.6% |
| Isc | 13.67 A | 13.4 A | 2.0% |
| Impp | 12.85 A | 12.94 A | 0.7% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 41.75 V | 1.6% |
| Vmpp | 33.49 V | 34.03 V | 1.6% |
| Isc | 13.67 A | 14.07 A | 2.9% |
| Impp | 12.85 A | 13.23 A | 3.0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 40.87 V | 0.5% |
| Vmpp | 33.49 V | 33.76 V | 0.8% |
| Isc | 13.67 A | 14.1 A | 3.1% |
| Impp | 12.85 A | 13.34 A | 3.8% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 40.68 V | 1.0% |
| Vmpp | 33.49 V | 33.6 V | 0.3% |
| Isc | 13.67 A | 14.01 A | 2.5% |
| Impp | 12.85 A | 13.25 A | 3.1% |
| TcVoc | -0.26 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.24 %/°C | -0.29 %/°C | ±0.050 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 40.56 V | 1.3% |
| Vmpp | 33.49 V | 33.75 V | 0.8% |
| Isc | 13.67 A | 13.35 A | 2.3% |
| Impp | 12.85 A | 12.89 A | 0.3% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 41.34 V | 0.6% |
| Vmpp | 33.49 V | 34.51 V | 3.0% |
| Isc | 13.67 A | 13.5 A | 1.2% |
| Impp | 12.85 A | 13.04 A | 1.5% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 41.8 V | 1.7% |
| Vmpp | 33.49 V | 34.07 V | 1.7% |
| Isc | 13.67 A | 13.13 A | 4.0% |
| Impp | 12.85 A | 12.34 A | 4.0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.09 V | 41.8 V | 1.7% |
| Vmpp | 33.49 V | 34.07 V | 1.7% |
| Isc | 13.67 A | 13.13 A | 4.0% |
| Impp | 12.85 A | 12.34 A | 4.0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
41.09 V
Vmpp
33.49 V
Isc
13.67 A
Impp
12.85 A
TcVoc
-0.26 %/°C
TcPmax
-0.24 %/°C
Pmax
430 W
Cells
108
Bifaciality
88%
Length
1722 mm
Width
1134 mm
Thickness
30 mm
Weight
24 kg
The Luxor Solar LX-430M/182-108+ GG HJT BW ECOLINE is a 430 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| LX-435M/182-108+ GG HJT BW ECOLINE | 435 W | 41.25 V | 13.78 A |
| LX-440M/182-108+ GG HJT BW ECOLINE | 440 W | 41.41 V | 13.88 A |
| LX-445M/182-108+ GG HJT BW ECOLINE | 445 W | 41.58 V | 13.98 A |
| LX-450M/182-108+ GG HJT BW ECOLINE | 450 W | 41.75 V | 14.07 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 41.09 V (within ±5%), and temperature coefficient TcVoc close to -0.26%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Luxor Solar LX-430M/182-108+ GG HJT BW ECOLINE.