445 W PERC solar panel with 144 cells. Voc 49.34 V · Isc 11.34 A · TcVoc -0.285%/°C.
Select the panel you want to replace
28 panels found · 3672 panels excluded
430 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.39 V | 0.1% |
| Vmpp | 41.44 V | 41.01 V | 1.0% |
| Isc | 11.34 A | 11.19 A | 1.3% |
| Impp | 10.74 A | 10.49 A | 2.3% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.69 V | 0.7% |
| Vmpp | 41.44 V | 41.41 V | 0.1% |
| Isc | 11.34 A | 11.34 A | 0.0% |
| Impp | 10.74 A | 10.63 A | 1.0% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
440 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49 V | 0.7% |
| Vmpp | 41.44 V | 41.16 V | 0.7% |
| Isc | 11.34 A | 11.3 A | 0.4% |
| Impp | 10.74 A | 10.7 A | 0.4% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.68 V | 0.7% |
| Vmpp | 41.44 V | 41.73 V | 0.7% |
| Isc | 11.34 A | 11.39 A | 0.4% |
| Impp | 10.74 A | 10.79 A | 0.5% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
435 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.59 V | 0.5% |
| Vmpp | 41.44 V | 41.21 V | 0.6% |
| Isc | 11.34 A | 11.25 A | 0.8% |
| Impp | 10.74 A | 10.56 A | 1.7% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.35 V | 0.0% |
| Vmpp | 41.44 V | 41.51 V | 0.2% |
| Isc | 11.34 A | 11.44 A | 0.9% |
| Impp | 10.74 A | 10.96 A | 2.0% |
| TcVoc | -0.285 %/°C | -0.27 %/°C | ±0.015 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.2 V | 0.3% |
| Vmpp | 41.44 V | 41.4 V | 0.1% |
| Isc | 11.34 A | 11.61 A | 2.4% |
| Impp | 10.74 A | 10.87 A | 1.2% |
| TcVoc | -0.285 %/°C | -0.304 %/°C | ±0.019 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
425 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.19 V | 0.3% |
| Vmpp | 41.44 V | 40.81 V | 1.5% |
| Isc | 11.34 A | 11.11 A | 2.0% |
| Impp | 10.74 A | 10.42 A | 3.0% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
450 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.05 V | 0.6% |
| Vmpp | 41.44 V | 41.32 V | 0.3% |
| Isc | 11.34 A | 11.37 A | 0.3% |
| Impp | 10.74 A | 10.89 A | 1.4% |
| TcVoc | -0.285 %/°C | -0.27 %/°C | ±0.015 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
455 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.4 V | 0.1% |
| Vmpp | 41.44 V | 41.6 V | 0.4% |
| Isc | 11.34 A | 11.68 A | 3.0% |
| Impp | 10.74 A | 10.94 A | 1.9% |
| TcVoc | -0.285 %/°C | -0.304 %/°C | ±0.019 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49.89 V | 1.1% |
| Vmpp | 41.44 V | 41.61 V | 0.4% |
| Isc | 11.34 A | 11.41 A | 0.6% |
| Impp | 10.74 A | 10.7 A | 0.4% |
| TcVoc | -0.285 %/°C | -0.285 %/°C | ±0.000 %/°C |
| TcPmax | -0.36 %/°C | -0.35 %/°C | ±0.010 %/°C |
445 W
PERC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.34 V | 49 V | 0.7% |
| Vmpp | 41.44 V | 41.2 V | 0.6% |
| Isc | 11.34 A | 11.54 A | 1.8% |
| Impp | 10.74 A | 10.81 A | 0.7% |
| TcVoc | -0.285 %/°C | -0.304 %/°C | ±0.019 %/°C |
| TcPmax | -0.36 %/°C | -0.36 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.34 V
Vmpp
41.44 V
Isc
11.34 A
Impp
10.74 A
TcVoc
-0.285 %/°C
TcPmax
-0.36 %/°C
Pmax
445 W
Cells
144
Length
2094 mm
Width
1038 mm
Thickness
35 mm
Weight
23.5 kg
The Luxor Solar LX-445M/166-144+ SW HC is a 445 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 440 W | 49 V | 11.3 A | |
| 450 W | 49.68 V | 11.39 A | |
| 455 W | 50.03 V | 11.44 A | |
| 460 W | 50.38 V | 11.49 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 49.34 V (within ±5%), and temperature coefficient TcVoc close to -0.285%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Luxor Solar LX-445M/166-144+ SW HC.