455 W TOPCon solar panel with 108 cells. Voc 41.07 V · Isc 14.19 A · TcVoc -0.25%/°C.
Select the panel you want to replace
60 panels found · 3640 panels excluded
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.87 V | 0.5% |
| Vmpp | 33.92 V | 33.76 V | 0.5% |
| Isc | 14.19 A | 14.1 A | 0.6% |
| Impp | 13.42 A | 13.34 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.85 V | 0.5% |
| Vmpp | 33.92 V | 34.51 V | 1.7% |
| Isc | 14.19 A | 14.38 A | 1.3% |
| Impp | 13.42 A | 13.48 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.68 V | 0.9% |
| Vmpp | 33.92 V | 33.6 V | 0.9% |
| Isc | 14.19 A | 14.01 A | 1.3% |
| Impp | 13.42 A | 13.25 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.65 V | 1.0% |
| Vmpp | 33.92 V | 34.31 V | 1.1% |
| Isc | 14.19 A | 14.31 A | 0.8% |
| Impp | 13.42 A | 13.41 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.84 V | 0.6% |
| Vmpp | 33.92 V | 33.86 V | 0.2% |
| Isc | 14.19 A | 14.42 A | 1.6% |
| Impp | 13.42 A | 13.74 A | 2.4% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.31 %/°C | ±0.020 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.45 V | 1.5% |
| Vmpp | 33.92 V | 34.11 V | 0.6% |
| Isc | 14.19 A | 14.24 A | 0.4% |
| Impp | 13.42 A | 13.34 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
450 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.25 V | 2.0% |
| Vmpp | 33.92 V | 33.91 V | 0.0% |
| Isc | 14.19 A | 14.17 A | 0.1% |
| Impp | 13.42 A | 13.27 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 41.09 V | 0.0% |
| Vmpp | 33.92 V | 34.26 V | 1.0% |
| Isc | 14.19 A | 13.45 A | 5.2% |
| Impp | 13.42 A | 12.99 A | 3.2% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.26 %/°C | ±0.030 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.48 V | 1.4% |
| Vmpp | 33.92 V | 33.44 V | 1.4% |
| Isc | 14.19 A | 13.92 A | 1.9% |
| Impp | 13.42 A | 13.17 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.05 V | 2.5% |
| Vmpp | 33.92 V | 33.71 V | 0.6% |
| Isc | 14.19 A | 14.1 A | 0.6% |
| Impp | 13.42 A | 13.2 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 40.16 V | 2.2% |
| Vmpp | 33.92 V | 33.84 V | 0.2% |
| Isc | 14.19 A | 14.46 A | 1.9% |
| Impp | 13.42 A | 13.6 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 41.07 V | 39.94 V | 2.8% |
| Vmpp | 33.92 V | 33.64 V | 0.8% |
| Isc | 14.19 A | 14.43 A | 1.7% |
| Impp | 13.42 A | 13.53 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
41.07 V
Vmpp
33.92 V
Isc
14.19 A
Impp
13.42 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
455 W
Cells
108
Bifaciality
80%
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
24.5 kg
The Luxor Solar LX-455M/182R186-108+ GG BW ECOLINE is a 455 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 435 W | 40.29 V | 13.83 A | |
| 440 W | 40.48 V | 13.92 A | |
| 445 W | 40.68 V | 14.01 A | |
| 450 W | 40.87 V | 14.1 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 41.07 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Luxor Solar LX-455M/182R186-108+ GG BW ECOLINE.