460 W HJT solar panel with 96 cells. Voc 38.32 V · Isc 15.68 A · TcVoc -0.26%/°C.
Select the panel you want to replace
22 panels found · 3678 panels excluded
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.31 V | 0.0% |
| Vmpp | 31.23 V | 31.22 V | 0.0% |
| Isc | 15.68 A | 15.86 A | 1.1% |
| Impp | 14.74 A | 14.91 A | 1.2% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.16 V | 0.4% |
| Vmpp | 31.23 V | 31.1 V | 0.4% |
| Isc | 15.68 A | 15.74 A | 0.4% |
| Impp | 14.74 A | 14.8 A | 0.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.17 V | 0.4% |
| Vmpp | 31.23 V | 31.11 V | 0.4% |
| Isc | 15.68 A | 15.57 A | 0.7% |
| Impp | 14.74 A | 14.64 A | 0.7% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.47 V | 0.4% |
| Vmpp | 31.23 V | 31.35 V | 0.4% |
| Isc | 15.68 A | 15.79 A | 0.7% |
| Impp | 14.74 A | 14.84 A | 0.7% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.45 V | 0.3% |
| Vmpp | 31.23 V | 31.34 V | 0.4% |
| Isc | 15.68 A | 15.97 A | 1.8% |
| Impp | 14.74 A | 15.01 A | 1.8% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.01 V | 0.8% |
| Vmpp | 31.23 V | 30.98 V | 0.8% |
| Isc | 15.68 A | 15.64 A | 0.3% |
| Impp | 14.74 A | 14.7 A | 0.3% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.32 V | 0.0% |
| Vmpp | 31.23 V | 31.23 V | 0.0% |
| Isc | 15.68 A | 15.68 A | 0.0% |
| Impp | 14.74 A | 14.74 A | 0.0% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.02 V | 0.8% |
| Vmpp | 31.23 V | 30.99 V | 0.8% |
| Isc | 15.68 A | 15.46 A | 1.4% |
| Impp | 14.74 A | 14.53 A | 1.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.61 V | 0.8% |
| Vmpp | 31.23 V | 31.47 V | 0.8% |
| Isc | 15.68 A | 16.06 A | 2.4% |
| Impp | 14.74 A | 15.1 A | 2.4% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.17 V | 0.4% |
| Vmpp | 31.23 V | 31.11 V | 0.4% |
| Isc | 15.68 A | 15.57 A | 0.7% |
| Impp | 14.74 A | 14.64 A | 0.7% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 38.47 V | 0.4% |
| Vmpp | 31.23 V | 31.35 V | 0.4% |
| Isc | 15.68 A | 15.79 A | 0.7% |
| Impp | 14.74 A | 14.84 A | 0.7% |
| TcVoc | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
| TcPmax | -0.24 %/°C | -0.26 %/°C | ±0.020 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 38.32 V | 37.87 V | 1.2% |
| Vmpp | 31.23 V | 30.86 V | 1.2% |
| Isc | 15.68 A | 15.52 A | 1.0% |
| Impp | 14.74 A | 14.59 A | 1.0% |
| TcVoc | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
| TcPmax | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
38.32 V
Vmpp
31.23 V
Isc
15.68 A
Impp
14.74 A
TcVoc
-0.26 %/°C
TcPmax
-0.24 %/°C
Pmax
460 W
Cells
96
Bifaciality
95%
Length
1756 mm
Width
1128 mm
Thickness
5 mm
Weight
23.5 kg
The Luxor Solar LX-460M/182R-96+ GG HJT FLT ECOLINE is a 460 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 445 W | 37.88 V | 15.35 A | |
| 450 W | 38.02 V | 15.46 A | |
| 455 W | 38.17 V | 15.57 A | |
| 465 W | 38.47 V | 15.79 A |
The most critical specs to match are: cell count (must be exactly 96), Voc close to 38.32 V (within ±5%), and temperature coefficient TcVoc close to -0.26%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Luxor Solar LX-460M/182R-96+ GG HJT FLT ECOLINE.