570 W TOPCon solar panel with 144 cells. Voc 51.48 V · Isc 14.15 A · TcVoc -0.25%/°C.
Select the panel you want to replace
185 panels found · 3515 panels excluded
570 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.48 V | 0.0% |
| Vmpp | 42.52 V | 42.52 V | 0.0% |
| Isc | 14.15 A | 14.15 A | 0.0% |
| Impp | 13.41 A | 13.41 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.48 V | 0.0% |
| Vmpp | 42.52 V | 42.75 V | 0.5% |
| Isc | 14.15 A | 14.08 A | 0.5% |
| Impp | 13.41 A | 13.57 A | 1.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.47 V | 0.0% |
| Vmpp | 42.52 V | 42.59 V | 0.2% |
| Isc | 14.15 A | 14.37 A | 1.6% |
| Impp | 13.41 A | 13.62 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.47 V | 0.0% |
| Vmpp | 42.52 V | 42.59 V | 0.2% |
| Isc | 14.15 A | 14.37 A | 1.6% |
| Impp | 13.41 A | 13.62 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.57 V | 0.2% |
| Vmpp | 42.52 V | 42.84 V | 0.8% |
| Isc | 14.15 A | 14.18 A | 0.2% |
| Impp | 13.41 A | 13.66 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.33 V | 0.3% |
| Vmpp | 42.52 V | 42.6 V | 0.2% |
| Isc | 14.15 A | 14 A | 1.1% |
| Impp | 13.41 A | 13.5 A | 0.7% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.42 V | 0.1% |
| Vmpp | 42.52 V | 42.71 V | 0.4% |
| Isc | 14.15 A | 14.37 A | 1.6% |
| Impp | 13.41 A | 13.58 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
580 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.42 V | 0.1% |
| Vmpp | 42.52 V | 42.68 V | 0.4% |
| Isc | 14.15 A | 14.32 A | 1.2% |
| Impp | 13.41 A | 13.59 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.49 V | 0.0% |
| Vmpp | 42.52 V | 42.68 V | 0.4% |
| Isc | 14.15 A | 13.89 A | 1.8% |
| Impp | 13.41 A | 13.24 A | 1.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
585 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.48 V | 0.0% |
| Vmpp | 42.52 V | 42.78 V | 0.6% |
| Isc | 14.15 A | 14.5 A | 2.5% |
| Impp | 13.41 A | 13.7 A | 2.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
575 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.27 V | 0.4% |
| Vmpp | 42.52 V | 42.44 V | 0.2% |
| Isc | 14.15 A | 14.31 A | 1.1% |
| Impp | 13.41 A | 13.55 A | 1.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.29 %/°C | ±0.010 %/°C |
565 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 51.48 V | 51.17 V | 0.6% |
| Vmpp | 42.52 V | 42.27 V | 0.6% |
| Isc | 14.15 A | 14.1 A | 0.4% |
| Impp | 13.41 A | 13.37 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.3 %/°C | -0.3 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
51.48 V
Vmpp
42.52 V
Isc
14.15 A
Impp
13.41 A
TcVoc
-0.25 %/°C
TcPmax
-0.3 %/°C
Pmax
570 W
Cells
144
Bifaciality
80%
Length
2279 mm
Width
1134 mm
Thickness
30 mm
Weight
32.7 kg
The Luxor Solar LX-570M/182-144+ GG SW ECOLINE is a 570 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 555 W | 50.57 V | 14.02 A | |
| 560 W | 50.87 V | 14.06 A | |
| 565 W | 51.17 V | 14.1 A | |
| 575 W | 51.79 V | 14.19 A |
The most critical specs to match are: cell count (must be exactly 144), Voc close to 51.48 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Luxor Solar LX-570M/182-144+ GG SW ECOLINE.