615 W TOPCon solar panel with 132 cells. Voc 48.46 V · Isc 16.25 A · TcVoc -0.25%/°C.
Select the panel you want to replace
168 panels found · 3542 panels excluded
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.46 V | 0.0% |
| Vmpp | 40.03 V | 40.03 V | 0.0% |
| Isc | 16.25 A | 16.25 A | 0.0% |
| Impp | 15.37 A | 15.37 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.46 V | 0.0% |
| Vmpp | 40.03 V | 40.03 V | 0.0% |
| Isc | 16.25 A | 16.25 A | 0.0% |
| Impp | 15.37 A | 15.37 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.46 V | 0.0% |
| Vmpp | 40.03 V | 40.03 V | 0.0% |
| Isc | 16.25 A | 16.25 A | 0.0% |
| Impp | 15.37 A | 15.37 A | 0.0% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.5 V | 0.1% |
| Vmpp | 40.03 V | 40.21 V | 0.4% |
| Isc | 16.25 A | 16.13 A | 0.7% |
| Impp | 15.37 A | 15.42 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.3 V | 0.3% |
| Vmpp | 40.03 V | 39.96 V | 0.2% |
| Isc | 16.25 A | 16.1 A | 0.9% |
| Impp | 15.37 A | 15.39 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.5 V | 0.1% |
| Vmpp | 40.03 V | 40.24 V | 0.5% |
| Isc | 16.25 A | 16.26 A | 0.1% |
| Impp | 15.37 A | 15.41 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.5 V | 0.1% |
| Vmpp | 40.03 V | 40.24 V | 0.5% |
| Isc | 16.25 A | 16.26 A | 0.1% |
| Impp | 15.37 A | 15.41 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.5 V | 0.1% |
| Vmpp | 40.03 V | 40.24 V | 0.5% |
| Isc | 16.25 A | 16.26 A | 0.1% |
| Impp | 15.37 A | 15.41 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.23 V | 0.5% |
| Vmpp | 40.03 V | 39.84 V | 0.5% |
| Isc | 16.25 A | 16.19 A | 0.4% |
| Impp | 15.37 A | 15.32 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.69 V | 0.5% |
| Vmpp | 40.03 V | 40.22 V | 0.5% |
| Isc | 16.25 A | 16.3 A | 0.3% |
| Impp | 15.37 A | 15.42 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.69 V | 0.5% |
| Vmpp | 40.03 V | 40.22 V | 0.5% |
| Isc | 16.25 A | 16.3 A | 0.3% |
| Impp | 15.37 A | 15.42 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 48.46 V | 48.23 V | 0.5% |
| Vmpp | 40.03 V | 39.84 V | 0.5% |
| Isc | 16.25 A | 16.19 A | 0.4% |
| Impp | 15.37 A | 15.32 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
48.46 V
Vmpp
40.03 V
Isc
16.25 A
Impp
15.37 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
615 W
Cells
132
Bifaciality
80%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
33.5 kg
The Luxor Solar LX-615M/182R-132+ GG SW PRO is a 615 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| LX-600M/182R-132+ GG SW PRO | 600 W | 47.77 V | 16.08 A |
| LX-605M/182R-132+ GG SW PRO | 605 W | 48 V | 16.14 A |
| LX-610M/182R-132+ GG SW PRO | 610 W | 48.23 V | 16.19 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 48.46 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Luxor Solar LX-615M/182R-132+ GG SW PRO.