Solar Stack
Solar Stack
How it worksGuidesAdd Equipment
Sign in
Solar Stack

Free solar panel & inverter compatibility checker. Verify your PV string configuration is safe before installation.

Tools

  • Calculator
  • Panel Matcher
  • Inverter Finder
  • Inverter Compare
  • Panel Replacement
  • Cable sizing

Resources

  • Guides
  • How it works
  • Standards & Compliance
  • Data API
  • Replacement methodology
  • Add Equipment
  • Feedback

Legal

  • About
  • Support
  • Privacy Policy
  • Terms of Service
  • Cookie Policy

© 2026 Solar Stack

All replacements

Find replacement for Maysun Solar MS445BC-54HB

445 W IBC solar panel with 108 cells. Voc 40.03 V · Isc 14.23 A · TcVoc -0.23%/°C.

Select the panel you want to replace

Panel not in the catalogue?

176 of the 4,444 panels in the catalogue can replace Maysun Solar MS445BC-54HB. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Exact match

Near-identical electrics — a drop-in swap for the same string.

Match 100 % · 2 models

  • LONGi LR5-54HTB-445M — Open the panel page
    445 WHPBC
    100 %
  • Perlight Solar PLM-445H8NB-108 Delta Plus — Open the panel page
    445 WHPBC
    100 %

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 80–91 % · 32 models

  • LONGi LR5-54HTH-450M — Open the panel page
    450 WHPBC
    91 %
  • LONGi LR5-54HTH-455M — Open the panel page
    455 WHPBC
    91 %
  • Maysun Solar MS450BC-54H — Open the panel page
    450 WIBC
    91 %
  • Perlight Solar PLM-450H8NB-108 BW BC — Open the panel page
    450 WHPBC
    91 %
  • Maysun Solar MS440BC-54HB — Open the panel page
    440 WIBCsame series
    90 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 60–79 % · 62 models

  • Horay Solar HS440TC-MHO — Open the panel page
    440 WTOPCon
    79 %
  • JinkoSolar JKM455N-54HL4R-(V) — Open the panel page
    455 WTOPCon
    79 %
  • JinkoSolar JKM460N-54HL4R-(V) — Open the panel page
    460 WTOPCon
    79 %
  • Horay Solar HS445TC-MHA — Open the panel page
    445 WTOPCon
    76 %
  • LONGi LR5-54HTH-440M — Open the panel page
    440 WHPBC
    76 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 37–59 % · 80 models

  • Maysun Solar MS425BC-54HB — Open the panel page
    425 WIBCsame series
    59 %
  • LONGi LR5-54HTB-425M — Open the panel page
    425 WHPBC
    59 %
  • Perlight Solar PLM-460H8NG-108 BW BC — Open the panel page
    460 WHPBC
    59 %
  • Aiko Solar AIKO-A445-MAH54Tm — Open the panel page
    445 WABC
    58 %
  • Hanersun HN18N-54H445W — Open the panel page
    445 WTOPCon
    58 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

40.03 V

Vmpp

33.76 V

Isc

14.23 A

Impp

13.19 A

TcVoc

-0.23 %/°C

TcPmax

-0.29 %/°C

Pmax

445 W

Cells

108

Length

1722 mm

Width

1134 mm

Thickness

30 mm

Weight

20.8 kg

The Maysun Solar MS445BC-54HB is a 445 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
MS425BC-54HB425 W39.23 V13.94 A
MS430BC-54HB430 W39.43 V14.01 A
MS435BC-54HB435 W39.63 V14.08 A
MS440BC-54HB440 W39.83 V14.15 A
MS450BC-54HB450 W40.23 V14.31 A

Frequently Asked Questions

What specs must match when replacing the Maysun Solar MS445BC-54HB?

The most critical specs to match are: cell count (must be exactly 108), Voc close to 40.03 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the Maysun Solar MS445BC-54HB?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Maysun Solar MS445BC-54HB.