715 W TOPCon solar panel with 132 cells. Voc 49.26 V · Isc 18.36 A · TcVoc -0.25%/°C.
Select the panel you want to replace
26 panels found · 3485 panels excluded
715 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.2 V | 0.1% |
| Vmpp | 41.17 V | 41.1 V | 0.2% |
| Isc | 18.36 A | 18.44 A | 0.4% |
| Impp | 17.38 A | 17.4 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.01 V | 0.5% |
| Vmpp | 41.17 V | 41.02 V | 0.4% |
| Isc | 18.36 A | 18.31 A | 0.3% |
| Impp | 17.38 A | 17.35 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.51 V | 0.5% |
| Vmpp | 41.17 V | 41.33 V | 0.4% |
| Isc | 18.36 A | 18.4 A | 0.2% |
| Impp | 17.38 A | 17.44 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.4 V | 0.3% |
| Vmpp | 41.17 V | 41.3 V | 0.3% |
| Isc | 18.36 A | 18.48 A | 0.7% |
| Impp | 17.38 A | 17.44 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
725 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.58 V | 0.6% |
| Vmpp | 41.17 V | 41.48 V | 0.8% |
| Isc | 18.36 A | 18.54 A | 1.0% |
| Impp | 17.38 A | 17.48 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49 V | 0.5% |
| Vmpp | 41.17 V | 40.9 V | 0.7% |
| Isc | 18.36 A | 18.4 A | 0.2% |
| Impp | 17.38 A | 17.36 A | 0.1% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
710 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.34 V | 0.2% |
| Vmpp | 41.17 V | 41.12 V | 0.1% |
| Isc | 18.36 A | 18.04 A | 1.7% |
| Impp | 17.38 A | 17.27 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.35 %/°C | ±0.060 %/°C |
705 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 48.76 V | 1.0% |
| Vmpp | 41.17 V | 40.85 V | 0.8% |
| Isc | 18.36 A | 18.26 A | 0.5% |
| Impp | 17.38 A | 17.27 A | 0.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
720 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.7 V | 0.9% |
| Vmpp | 41.17 V | 41.5 V | 0.8% |
| Isc | 18.36 A | 18.51 A | 0.8% |
| Impp | 17.38 A | 17.35 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.2 V | 0.1% |
| Vmpp | 41.17 V | 41.1 V | 0.2% |
| Isc | 18.36 A | 18.8 A | 2.4% |
| Impp | 17.38 A | 17.89 A | 2.9% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.32 %/°C | ±0.030 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.2 V | 0.1% |
| Vmpp | 41.17 V | 41.1 V | 0.2% |
| Isc | 18.36 A | 18.8 A | 2.4% |
| Impp | 17.38 A | 17.89 A | 2.9% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.32 %/°C | ±0.030 %/°C |
735 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.26 V | 49.2 V | 0.1% |
| Vmpp | 41.17 V | 41.1 V | 0.2% |
| Isc | 18.36 A | 18.8 A | 2.4% |
| Impp | 17.38 A | 17.89 A | 2.9% |
| TcVoc | -0.25 %/°C | -0.26 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.32 %/°C | ±0.030 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.26 V
Vmpp
41.17 V
Isc
18.36 A
Impp
17.38 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
715 W
Cells
132
Length
2384 mm
Width
1303 mm
Thickness
30 mm
Weight
40 kg
The Maysun Solar MS715MTDG-66HN is a 715 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 700 W | 48.51 V | 18.22 A | |
| 705 W | 48.76 V | 18.26 A | |
| 710 W | 49.01 V | 18.31 A | |
| 720 W | 49.51 V | 18.4 A | |
| 725 W | 49.58 V | 18.54 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.26 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Maysun Solar MS715MTDG-66HN.