Find replacement for München Solar MSMD380M6-60

380 W PERC solar panel with 120 cells. Voc 41.4 V · Isc 11.63 A · TcVoc -0.304%/°C.

Select the panel you want to replace

Panel not in the catalogue?

21 of the 4,444 panels in the catalogue can replace München Solar MSMD380M6-60. Before you buy, check your pick in the string calculator with your inverter.

CloseNoticeableLarge differenceTap or click a difference to see what it means for your string.

Good match

Small differences within tolerance — safe once verified in the calculator with your inverter.

Match 85–90 % · 2 models

  • München Solar MSMD375M6-60 — Open the panel page
    375 WPERCsame series
    90 %
  • WINAICO WST-380MGL — Open the panel page
    380 WPERC
    85 %

Acceptable

Noticeable differences — the string voltage and current need a careful check.

Match 60–79 % · 11 models

  • S-Energy SL45-60MAI-375Z — Open the panel page
    375 WPERC
    79 %
  • S-Energy SL45-60MBI-375Z — Open the panel page
    375 WPERC
    79 %
  • S-Energy SL45-60MCI-375Z — Open the panel page
    375 WPERC
    79 %
  • München Solar MSMD370M6-60 — Open the panel page
    370 WPERCsame series
    76 %
  • WINAICO WST-375MGL — Open the panel page
    375 WPERC
    73 %

Marginal

Large differences — a real risk of a mismatched string; prefer a closer panel.

Match 47–58 % · 8 models

  • München Solar MSMD360M6-60 — Open the panel page
    360 WPERCsame series
    58 %
  • S-Energy SL45-60MAI-365Z — Open the panel page
    365 WPERC
    57 %
  • S-Energy SL45-60MBI-365Z — Open the panel page
    365 WPERC
    57 %
  • S-Energy SL45-60MCI-365Z — Open the panel page
    365 WPERC
    57 %
  • WINAICO WST-365MGL — Open the panel page
    365 WPERC
    48 %

String Compatibility Calculator

Verify the replacement panel works with your inverter

Panel Matcher

Find all compatible panels for a specific inverter

Already have panels?

Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.

How the Algorithm Works

Learn how panels are scored and matched

Original Panel Specs

Voc

41.4 V

Vmpp

34.7 V

Isc

11.63 A

Impp

10.95 A

TcVoc

-0.304 %/°C

TcPmax

-0.35 %/°C

Pmax

380 W

Cells

120

Length

1756 mm

Width

1039 mm

Thickness

35 mm

Weight

19.8 kg

The München Solar MSMD380M6-60 is a 380 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.

Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.

Other models in this series

ModelPowerVocIsc
MSMD360M6-60360 W40.5 V11.35 A
MSMD365M6-60365 W40.7 V11.42 A
MSMD370M6-60370 W40.9 V11.49 A
MSMD375M6-60375 W41.2 V11.56 A

Frequently Asked Questions

What specs must match when replacing the München Solar MSMD380M6-60?

The most critical specs to match are: cell count (must be exactly 120), Voc close to 41.4 V (within ±5%), and temperature coefficient TcVoc close to -0.304%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.

Can I use a higher wattage replacement for the München Solar MSMD380M6-60?

A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.

What happens if the replacement panel has different voltage specs?

If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original München Solar MSMD380M6-60.