615 W TOPCon solar panel with 132 cells. Voc 49.22 V · Isc 15.52 A · TcVoc -0.25%/°C.
Select the panel you want to replace
196 panels found · 4143 panels excluded
605 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.19 V | 0.1% |
| Vmpp | 41.36 V | 41.44 V | 0.2% |
| Isc | 15.52 A | 15.46 A | 0.4% |
| Impp | 14.87 A | 14.6 A | 1.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 48.98 V | 0.5% |
| Vmpp | 41.36 V | 41.24 V | 0.3% |
| Isc | 15.52 A | 15.41 A | 0.7% |
| Impp | 14.87 A | 14.55 A | 2.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
610 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 48.95 V | 0.5% |
| Vmpp | 41.36 V | 41.11 V | 0.6% |
| Isc | 15.52 A | 15.48 A | 0.3% |
| Impp | 14.87 A | 14.84 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.5 V | 0.6% |
| Vmpp | 41.36 V | 41.62 V | 0.6% |
| Isc | 15.52 A | 15.56 A | 0.3% |
| Impp | 14.87 A | 14.9 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.32 V | 0.2% |
| Vmpp | 41.36 V | 41.11 V | 0.6% |
| Isc | 15.52 A | 15.97 A | 2.9% |
| Impp | 14.87 A | 15.09 A | 1.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
600 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.02 V | 0.4% |
| Vmpp | 41.36 V | 41.12 V | 0.6% |
| Isc | 15.52 A | 15.4 A | 0.8% |
| Impp | 14.87 A | 14.59 A | 1.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.19 V | 0.1% |
| Vmpp | 41.36 V | 41.69 V | 0.8% |
| Isc | 15.52 A | 16.19 A | 4.3% |
| Impp | 14.87 A | 14.99 A | 0.8% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.12 V | 0.2% |
| Vmpp | 41.36 V | 40.91 V | 1.1% |
| Isc | 15.52 A | 15.92 A | 2.6% |
| Impp | 14.87 A | 15.04 A | 1.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.04 V | 0.4% |
| Vmpp | 41.36 V | 41.56 V | 0.5% |
| Isc | 15.52 A | 16.11 A | 3.8% |
| Impp | 14.87 A | 14.92 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.27 V | 0.1% |
| Vmpp | 41.36 V | 40.98 V | 0.9% |
| Isc | 15.52 A | 16.1 A | 3.7% |
| Impp | 14.87 A | 15.26 A | 2.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
615 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 48.89 V | 0.7% |
| Vmpp | 41.36 V | 41.43 V | 0.2% |
| Isc | 15.52 A | 16.02 A | 3.2% |
| Impp | 14.87 A | 14.84 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 49.22 V | 49.26 V | 0.1% |
| Vmpp | 41.36 V | 41.31 V | 0.1% |
| Isc | 15.52 A | 16.11 A | 3.8% |
| Impp | 14.87 A | 15.13 A | 1.7% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
49.22 V
Vmpp
41.36 V
Isc
15.52 A
Impp
14.87 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
615 W
Cells
132
Bifaciality
80%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
32.6 kg
The Phono Solar PS615L8GF-22/WNH is a 615 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| PS610L8GF-22/WNH | 610 W | 48.95 V | 15.48 A |
| PS620L8GF-22/WNH | 620 W | 49.5 V | 15.56 A |
| PS625L8GF-22/WNH | 625 W | 49.77 V | 15.6 A |
| PS630L8GF-22/WNH | 630 W | 50.04 V | 15.64 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 49.22 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Phono Solar PS615L8GF-22/WNH.