630 W TOPCon solar panel with 132 cells. Voc 50.04 V · Isc 15.64 A · TcVoc -0.25%/°C.
Select the panel you want to replace
187 panels found · 4152 panels excluded
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 49.77 V | 0.5% |
| Vmpp | 42.12 V | 41.87 V | 0.6% |
| Isc | 15.64 A | 15.6 A | 0.3% |
| Impp | 14.96 A | 14.93 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 50.2 V | 0.3% |
| Vmpp | 42.12 V | 42 V | 0.3% |
| Isc | 15.64 A | 16.09 A | 2.9% |
| Impp | 14.96 A | 15 A | 0.3% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
630 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 49.95 V | 0.2% |
| Vmpp | 42.12 V | 41.46 V | 1.6% |
| Isc | 15.64 A | 16.05 A | 2.6% |
| Impp | 14.96 A | 15.2 A | 1.6% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.3 %/°C | ±0.010 %/°C |
625 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 49.9 V | 0.3% |
| Vmpp | 42.12 V | 41.7 V | 1.0% |
| Isc | 15.64 A | 16.06 A | 2.7% |
| Impp | 14.96 A | 14.99 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 50.1 V | 0.1% |
| Vmpp | 42.12 V | 41.64 V | 1.1% |
| Isc | 15.64 A | 16.37 A | 4.7% |
| Impp | 14.96 A | 15.49 A | 3.5% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
650 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 49.87 V | 0.3% |
| Vmpp | 42.12 V | 42.24 V | 0.3% |
| Isc | 15.64 A | 16.58 A | 6.0% |
| Impp | 14.96 A | 15.39 A | 2.9% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 49.98 V | 0.1% |
| Vmpp | 42.12 V | 41.96 V | 0.4% |
| Isc | 15.64 A | 16.39 A | 4.8% |
| Impp | 14.96 A | 15.37 A | 2.7% |
| TcVoc | -0.25 %/°C | -0.24 %/°C | ±0.010 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 49.72 V | 0.6% |
| Vmpp | 42.12 V | 42.11 V | 0.0% |
| Isc | 15.64 A | 16.5 A | 5.5% |
| Impp | 14.96 A | 15.32 A | 2.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 50.08 V | 0.1% |
| Vmpp | 42.12 V | 41.44 V | 1.6% |
| Isc | 15.64 A | 16.38 A | 4.7% |
| Impp | 14.96 A | 15.57 A | 4.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
645 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 50.08 V | 0.1% |
| Vmpp | 42.12 V | 41.44 V | 1.6% |
| Isc | 15.64 A | 16.38 A | 4.7% |
| Impp | 14.96 A | 15.57 A | 4.1% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
620 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 49.5 V | 1.1% |
| Vmpp | 42.12 V | 41.62 V | 1.2% |
| Isc | 15.64 A | 15.56 A | 0.5% |
| Impp | 14.96 A | 14.9 A | 0.4% |
| TcVoc | -0.25 %/°C | -0.25 %/°C | ±0.000 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
640 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 50.04 V | 50.1 V | 0.1% |
| Vmpp | 42.12 V | 42.7 V | 1.4% |
| Isc | 15.64 A | 15.87 A | 1.5% |
| Impp | 14.96 A | 14.99 A | 0.2% |
| TcVoc | -0.25 %/°C | -0.23 %/°C | ±0.020 %/°C |
| TcPmax | -0.29 %/°C | -0.29 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
50.04 V
Vmpp
42.12 V
Isc
15.64 A
Impp
14.96 A
TcVoc
-0.25 %/°C
TcPmax
-0.29 %/°C
Pmax
630 W
Cells
132
Bifaciality
80%
Length
2382 mm
Width
1134 mm
Thickness
30 mm
Weight
32.6 kg
The Phono Solar PS630L8GF-22/WNH is a 630 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| PS610L8GF-22/WNH | 610 W | 48.95 V | 15.48 A |
| PS615L8GF-22/WNH | 615 W | 49.22 V | 15.52 A |
| PS620L8GF-22/WNH | 620 W | 49.5 V | 15.56 A |
| PS625L8GF-22/WNH | 625 W | 49.77 V | 15.6 A |
The most critical specs to match are: cell count (must be exactly 132), Voc close to 50.04 V (within ±5%), and temperature coefficient TcVoc close to -0.25%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original Phono Solar PS630L8GF-22/WNH.