445 W HJT solar panel with 96 cells. Voc 36.95 V · Isc 15.3 A · TcVoc -0.24%/°C.
Select the panel you want to replace
140 panels found · 3560 panels excluded
440 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.68 V | 0.7% |
| Vmpp | 30.66 V | 30.43 V | 0.8% |
| Isc | 15.3 A | 15.26 A | 0.3% |
| Impp | 14.53 A | 14.47 A | 0.4% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
450 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 37.22 V | 0.7% |
| Vmpp | 30.66 V | 30.88 V | 0.7% |
| Isc | 15.3 A | 15.36 A | 0.4% |
| Impp | 14.53 A | 14.6 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.89 V | 0.2% |
| Vmpp | 30.66 V | 30.83 V | 0.6% |
| Isc | 15.3 A | 15.82 A | 3.4% |
| Impp | 14.53 A | 15.09 A | 3.9% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.91 V | 0.1% |
| Vmpp | 30.66 V | 30.78 V | 0.4% |
| Isc | 15.3 A | 15.81 A | 3.3% |
| Impp | 14.53 A | 14.94 A | 2.8% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.93 V | 0.1% |
| Vmpp | 30.66 V | 30.8 V | 0.5% |
| Isc | 15.3 A | 15.84 A | 3.5% |
| Impp | 14.53 A | 15.1 A | 3.9% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
450 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.82 V | 0.4% |
| Vmpp | 30.66 V | 30.83 V | 0.6% |
| Isc | 15.3 A | 15.53 A | 1.5% |
| Impp | 14.53 A | 14.6 A | 0.5% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.68 V | 0.7% |
| Vmpp | 30.66 V | 30.6 V | 0.2% |
| Isc | 15.3 A | 15.76 A | 3.0% |
| Impp | 14.53 A | 15.04 A | 3.5% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
455 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 37.47 V | 1.4% |
| Vmpp | 30.66 V | 31.1 V | 1.4% |
| Isc | 15.3 A | 15.41 A | 0.7% |
| Impp | 14.53 A | 14.66 A | 0.9% |
| TcVoc | -0.24 %/°C | -0.24 %/°C | ±0.000 %/°C |
| TcPmax | -0.26 %/°C | -0.26 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.75 V | 0.5% |
| Vmpp | 30.66 V | 30.65 V | 0.0% |
| Isc | 15.3 A | 15.71 A | 2.7% |
| Impp | 14.53 A | 14.85 A | 2.2% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.9 V | 0.1% |
| Vmpp | 30.66 V | 30.73 V | 0.2% |
| Isc | 15.3 A | 15.98 A | 4.4% |
| Impp | 14.53 A | 15.13 A | 4.1% |
| TcVoc | -0.24 %/°C | -0.25 %/°C | ±0.010 %/°C |
| TcPmax | -0.26 %/°C | -0.29 %/°C | ±0.030 %/°C |
445 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.62 V | 0.9% |
| Vmpp | 30.66 V | 30.72 V | 0.2% |
| Isc | 15.3 A | 15.42 A | 0.8% |
| Impp | 14.53 A | 14.49 A | 0.3% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
455 W
HJT| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 36.95 V | 36.82 V | 0.4% |
| Vmpp | 30.66 V | 30.94 V | 0.9% |
| Isc | 15.3 A | 15.64 A | 2.2% |
| Impp | 14.53 A | 14.71 A | 1.2% |
| TcVoc | -0.24 %/°C | -0.22 %/°C | ±0.020 %/°C |
| TcPmax | -0.26 %/°C | -0.24 %/°C | ±0.020 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
36.95 V
Vmpp
30.66 V
Isc
15.3 A
Impp
14.53 A
TcVoc
-0.24 %/°C
TcPmax
-0.26 %/°C
Pmax
445 W
Cells
96
Bifaciality
90%
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
23 kg
The RECOM RCM-445-RDBHAA is a 445 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 440 W | 36.68 V | 15.26 A | |
| 450 W | 37.22 V | 15.36 A | |
| 455 W | 37.47 V | 15.41 A | |
| 460 W | 37.72 V | 15.45 A |
The most critical specs to match are: cell count (must be exactly 96), Voc close to 36.95 V (within ±5%), and temperature coefficient TcVoc close to -0.24%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original RECOM RCM-445-RDBHAA.