460 W TOPCon solar panel with 108 cells. Voc 39.1 V · Isc 14.87 A · TcVoc -0.23%/°C.
Select the panel you want to replace
96 panels found · 3604 panels excluded
455 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.15 V | 0.1% |
| Vmpp | 32.6 V | 32.98 V | 1.2% |
| Isc | 14.87 A | 14.79 A | 0.5% |
| Impp | 14.12 A | 13.8 A | 2.3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 38.9 V | 0.5% |
| Vmpp | 32.6 V | 32.4 V | 0.6% |
| Isc | 14.87 A | 14.8 A | 0.5% |
| Impp | 14.12 A | 14.05 A | 0.5% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
455 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.15 V | 0.1% |
| Vmpp | 32.6 V | 32.98 V | 1.2% |
| Isc | 14.87 A | 14.79 A | 0.5% |
| Impp | 14.12 A | 13.8 A | 2.3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
460 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.08 V | 0.1% |
| Vmpp | 32.6 V | 33.15 V | 1.7% |
| Isc | 14.87 A | 14.78 A | 0.6% |
| Impp | 14.12 A | 13.88 A | 1.7% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
465 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.26 V | 0.4% |
| Vmpp | 32.6 V | 33.3 V | 2.1% |
| Isc | 14.87 A | 14.87 A | 0.0% |
| Impp | 14.12 A | 13.96 A | 1.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
455 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 38.9 V | 0.5% |
| Vmpp | 32.6 V | 33 V | 1.2% |
| Isc | 14.87 A | 14.68 A | 1.3% |
| Impp | 14.12 A | 13.79 A | 2.3% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
460 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.35 V | 0.6% |
| Vmpp | 32.6 V | 33.19 V | 1.8% |
| Isc | 14.87 A | 14.86 A | 0.1% |
| Impp | 14.12 A | 13.86 A | 1.8% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
460 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.35 V | 0.6% |
| Vmpp | 32.6 V | 33.19 V | 1.8% |
| Isc | 14.87 A | 14.86 A | 0.1% |
| Impp | 14.12 A | 13.86 A | 1.8% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.08 V | 0.1% |
| Vmpp | 32.6 V | 32.63 V | 0.1% |
| Isc | 14.87 A | 14.59 A | 1.9% |
| Impp | 14.12 A | 13.8 A | 2.3% |
| TcVoc | -0.23 %/°C | -0.25 %/°C | ±0.020 %/°C |
| TcPmax | -0.28 %/°C | -0.29 %/°C | ±0.010 %/°C |
470 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.31 V | 0.5% |
| Vmpp | 32.6 V | 33.35 V | 2.3% |
| Isc | 14.87 A | 15.01 A | 0.9% |
| Impp | 14.12 A | 14.1 A | 0.1% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
445 W
TOPCon| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 38.9 V | 0.5% |
| Vmpp | 32.6 V | 32.9 V | 0.9% |
| Isc | 14.87 A | 14.33 A | 3.6% |
| Impp | 14.12 A | 13.53 A | 4.2% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
440 W
HPBC| Parameter | Original | Replacement | Deviation |
|---|---|---|---|
| Voc | 39.1 V | 39.3 V | 0.5% |
| Vmpp | 32.6 V | 32.82 V | 0.7% |
| Isc | 14.87 A | 14.23 A | 4.3% |
| Impp | 14.12 A | 13.41 A | 5.0% |
| TcVoc | -0.23 %/°C | -0.23 %/°C | ±0.000 %/°C |
| TcPmax | -0.28 %/°C | -0.28 %/°C | ±0.000 %/°C |
String Compatibility Calculator
Verify the replacement panel works with your inverter
Panel Matcher
Find all compatible panels for a specific inverter
Already have panels?
Find an inverter that fits your panel array with the right MPPT range and DC/AC ratio.
How the Algorithm Works
Learn how panels are scored and matched
Voc
39.1 V
Vmpp
32.6 V
Isc
14.87 A
Impp
14.12 A
TcVoc
-0.23 %/°C
TcPmax
-0.28 %/°C
Pmax
460 W
Cells
108
Length
1762 mm
Width
1134 mm
Thickness
30 mm
Weight
22 kg
The RECOM RCM-460-7NG is a 460 W solar panel. Finding a compatible replacement requires matching the original electrical characteristics — particularly Voc, Vmpp, Isc, and temperature coefficients — to ensure safe operation within the same string.
Use the form above to find panels that match these specifications. Then verify the replacement in the String Compatibility Calculator with your inverter.
| Model | Power | Voc | Isc |
|---|---|---|---|
| 440 W | 38.3 V | 14.59 A | |
| 445 W | 38.5 V | 14.66 A | |
| 450 W | 38.7 V | 14.73 A | |
| 455 W | 38.9 V | 14.8 A |
The most critical specs to match are: cell count (must be exactly 108), Voc close to 39.1 V (within ±5%), and temperature coefficient TcVoc close to -0.23%/°C. If Voc differs significantly, the string voltage at extreme temperatures may shift outside the inverter's MPPT range. The replacement finder above pre-screens all candidates by these criteria.
A higher wattage panel usually has a higher Vmpp or Isc, which can affect string voltage and current. Small increases (up to 10–15%) are typically safe if the other electrical specs align. The replacement finder shows a compatibility score — 'Exact match' means the specs align closely. Always verify the replacement in the String Compatibility Calculator with your inverter before installation.
If the replacement has a significantly different Voc or Vmpp, the string voltage may shift outside the inverter's MPPT range, reducing energy production or causing faults. This effect is amplified at temperature extremes: at low temperatures, voltage rises by the TcVoc coefficient. The replacement finder automatically accounts for this — it scores candidates by how closely the electrical specs match the original RECOM RCM-460-7NG.